C3 AC circuits · Practice
Real, reactive and apparent power; power factor
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A load draws 5 A RMS from 120 V RMS, with the current lagging by 60°. How much real power does it consume?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Same load: 120 V, 5 A, lagging by 60°. What is its reactive power?
Write units the way you normally would: 1.5 VAR, 1500 mVAR and 0.0015 kVAR are the same answer.
Check
A load takes 8 kW of real power and 4 kVAR of reactive power. What is its power factor?
Check
A load of 10 + j30 Ω carries 5 A RMS. How much real power does it consume?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A motor on a 120 V, 60 Hz supply draws 2 kVAR of reactive power. What capacitor across it would cancel that?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
Check
A load draws 2 A from 120 V, and a wattmeter reads 0.8 of the volt-amperes.
(a)
What real power does it take?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What's its reactive power?
Check
100 V RMS, 2 A RMS. Apparent power?
Write units the way you normally would: 1.5 VA, 1500 mVA and 0.0015 kVA are the same answer.
Check
10 kVA at power factor 0.6. Real power?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
Check
3 kW and 4 kVAR. Apparent power?
Write units the way you normally would: 1.5 kVA, 1500 VA and 0.0015 MVA are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in C3