C322 of 29
0 XP
  1. Hook
  2. Problems

C3 · Problem set 4

Problem set 4: AC power, three-phase and harmonics

These problems use lessons 16 to 20: real, reactive and apparent power, power factor correction, three-phase and split-phase systems, and non-sinusoidal waveforms. Voltages and currents are RMS unless a problem says otherwise.

Check

A load of 10 + j40 Ω is connected to 120 V.

(a)

What real power does it take?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

(b)

What is its power factor?

Check

A load takes 2 kW and 1 kVAR.

(a)

What is its apparent power?

Write units the way you normally would: 1.5 kVA, 1500 VA and 0.0015 MVA are the same answer.

(b)

What is the phase angle between voltage and current?

Check

A 15 kW single-phase load at pf 0.65 on 400 V, 50 Hz is corrected to pf 0.98.

(a)

What reactive power must the capacitors supply?

Write units the way you normally would: 1.5 kVAR, 1500 VAR and 0.0015 MVAR are the same answer.

(b)

What capacitance is that?

Check

A 5 kW load on 230 V is corrected from pf 0.7 to 0.97.

(a)

By how much does its supply current fall?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

By what percentage do the cable losses fall?

Check

A balanced wye load has 230 V per phase and draws 10 A at pf 0.92.

(a)

What is the line voltage?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

(b)

What total power does it take?

Check

A three-phase motor delivers 7.5 kW of mechanical power at efficiency 0.95, pf 0.88, from 400 V.

(a)

What electrical power does it take?

Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.

(b)

What line current does it draw?

Check

A balanced delta load of 10 Ω resistors per phase is connected to 208 V.

(a)

What line current does it draw?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What power does it take?

Check

A wye of resistive loads draws 15, 10 and 8 A.

(a)

What current flows in the neutral?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What would it carry if all three were in phase, as third harmonics are?

Check

A ±2 V square wave drives a 4 Ω resistor.

(a)

What power does it deliver?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

(b)

How much of that is in the fundamental?

Check

A voltage has a fundamental of 100 V RMS, with third and fifth harmonics of 2% and 5% of the fundamental.

(a)

What is its THD, in percent?

(b)

What is its total RMS?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A rectifier load draws 2 A RMS with 50% current THD, its fundamental in phase with the 230 V supply.

(a)

What is the fundamental current?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What real power does it take?

Check

A waveform has 5 V peak and 2 V RMS.

(a)

What is its crest factor?

(b)

What power does it deliver to 50 Ω?

Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.

Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.

Practice

Keep practicing

16 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.