C3 AC circuits · Practice
Problem set 4: AC power, three-phase and harmonics
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A load of 10 + j40 Ω is connected to 120 V.
(a)
What real power does it take?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What is its power factor?
Check
A load takes 2 kW and 1 kVAR.
(a)
What is its apparent power?
Write units the way you normally would: 1.5 kVA, 1500 VA and 0.0015 MVA are the same answer.
(b)
What is the phase angle between voltage and current?
Check
A 15 kW single-phase load at pf 0.65 on 400 V, 50 Hz is corrected to pf 0.98.
(a)
What reactive power must the capacitors supply?
Write units the way you normally would: 1.5 kVAR, 1500 VAR and 0.0015 MVAR are the same answer.
(b)
What capacitance is that?
Check
A 5 kW load on 230 V is corrected from pf 0.7 to 0.97.
(a)
By how much does its supply current fall?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
By what percentage do the cable losses fall?
Check
A balanced wye load has 230 V per phase and draws 10 A at pf 0.92.
(a)
What is the line voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What total power does it take?
Check
A three-phase motor delivers 7.5 kW of mechanical power at efficiency 0.95, pf 0.88, from 400 V.
(a)
What electrical power does it take?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
What line current does it draw?
Check
A balanced delta load of 10 Ω resistors per phase is connected to 208 V.
(a)
What line current does it draw?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What power does it take?
Check
A wye of resistive loads draws 15, 10 and 8 A.
(a)
What current flows in the neutral?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What would it carry if all three were in phase, as third harmonics are?
Check
A ±2 V square wave drives a 4 Ω resistor.
(a)
What power does it deliver?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
How much of that is in the fundamental?
Check
A voltage has a fundamental of 100 V RMS, with third and fifth harmonics of 2% and 5% of the fundamental.
(a)
What is its THD, in percent?
(b)
What is its total RMS?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A rectifier load draws 2 A RMS with 50% current THD, its fundamental in phase with the 230 V supply.
(a)
What is the fundamental current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What real power does it take?
Check
A waveform has 5 V peak and 2 V RMS.
(a)
What is its crest factor?
(b)
What power does it deliver to 50 Ω?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
Check
A load draws 3 A from 120 V at power factor 0.9.
(a)
What's its real power?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What's its reactive power?
Check
A 20 kW load at pf 0.7 is corrected to 0.98.
(a)
What reactive power must the capacitors supply?
Write units the way you normally would: 1.5 kvar, 1500 var and 0.0015 Mvar are the same answer.
(b)
What's the apparent power after correction?
Check
A triangle wave of peak 2 V, and a current with THD 0.3 whose fundamental is in phase.
(a)
What's the triangle's fundamental amplitude?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What's the current's power factor?
Check
A split-phase panel feeds 1500 W of 120 V loads on L1, 300 W on L2, and a 5400 W 240 V load.
(a)
What current flows in L2?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
If the neutral opens with the 240 V load off, what voltage reaches L2's loads?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in C3