C3 AC circuits · Practice
Split-phase power and home wiring
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A house draws 1200 W of resistive load on L1 and 300 W on L2, at 120 V each. What current does the neutral carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
L1 has 1500 W of 120 V loads, L2 has 500 W, and a 7200 W load runs from L1 to L2 at 240 V.
(a)
What current does L1 carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
And the neutral?
Check
The neutral opens while L1 has 1200 W of resistive load (rated at 120 V) and L2 has 100 W.
(a)
What voltage does L2's load see?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What power does L2's load dissipate?
Check
A 15 A load runs at 120 V on 15 m of cable with 3.28 mΩ/m conductors. What percentage of 120 V is lost in the wiring?
Check
L1 carries 12 A at power factor 0.9 lagging, and L2 carries 6 A at power factor 0.6 lagging.
(a)
What's the neutral current's magnitude?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Model a split-phase panel. The service conductors (each hot and the neutral) have Rs = 0.05 Ω from the transformer. Write panel(loads), where loads is a list of (leg, watts) with leg 1, 2 or 12 (a 240 V load) and watts rated at 120 V or 240 V, all resistive. Solve the circuit with the transformer as two ideal 120 V sources and return (v1, v2), the voltages across leg 1's and leg 2's 120 V loads. Use numpy.linalg.solve on the node equations. Also set open_v to panel_open([(1, 1200), (2, 600)])'s result for an open neutral (the neutral conductor's resistance infinite).
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
A 3600 W resistive load runs at 120 V. What current does it draw?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
With an open neutral, leg 1 has 800 W and leg 2 has 60 W of 120 V loads. What voltage does leg 2 see?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in C3