D2 · Lesson 9 · Capstone
A solar panel's current–voltage curve and its single maximum power point, why connecting a panel straight to a battery wastes half its power, how a buck converter's duty cycle sets the panel's operating voltage, and a perturb-and-observe tracker that finds the peak on its own as the sun changes
A solar panel is an awkward source. Short it and it delivers its full current at no voltage; leave it open and it holds its full voltage at no current; in between there's exactly one voltage at which it delivers the most power, and that voltage drifts with sunlight and temperature. A battery, meanwhile, insists on its own voltage. A maximum power point tracking (MPPT) charger is a DC-DC converter placed between them, with a small algorithm that keeps adjusting the duty cycle so that the panel always sits at its peak. This capstone puts the course's converter ideas to work on that problem.
- A 60-cell panel's power against its voltage, at a fraction G of full sun (8 A short-circuit current, 37 V open-circuit at full sun).
- A buck charger feeds a 13.5 V battery, so the panel's voltage is set by the duty cycle: (the dashed line).
- Move D to find the peak, then change the sunlight and watch the best duty cycle move: that's the tracker's job.
Predict
The panel makes 239 W at its peak, at 31.6 V. Connected straight to a 13.5 V battery, about how much power does it deliver?
At 13.5 V the panel is far below its knee and delivers almost its full short-circuit current, 8 A, so P ≈ 13.5 × 8 = 108 W, 45% of what it could make. A buck converter with D = 13.5/31.6 = 0.427 lets the panel run at 31.6 V while the battery takes 0.95 × 239/13.5 = 16.8 A, more than twice the current of a direct connection.
Name it
The panel
A panel behaves like a current source (proportional to sunlight) in parallel with a diode, so its current stays near until the voltage approaches and then collapses. Its power, VI, has a single peak, the maximum power point . The fill factor
measures how square the curve is, about 0.75 to 0.82 for silicon. Less sun lowers the current a lot and the voltage only a little; heat lowers the voltage.
The converter
A buck converter with duty cycle D between the panel and a battery forces (lesson 2), so choosing D chooses where on its curve the panel runs. Power is conserved apart from losses, so the battery's charging current is .
The tracker
Perturb and observe: change the operating voltage by a small step, measure the power, keep going the same way if it rose and reverse if it fell. It climbs to the peak and then hops back and forth across it. Smaller steps sit closer to the peak but track changing sunlight more slowly.
Worked example
The panel's peak at full sun is 31.64 V and 7.558 A, with = 37 V and = 8 A. Find its fill factor and the duty cycle that holds it at its peak while charging a 13.5 V battery.
Show the solution
- Fill factor.
- Duty cycle.
Answer the fill factor is 0.808, and a duty cycle of 0.427 holds the panel at its peak.
Worked example
With 5 hours of full-sun-equivalent light a day, what does the MPPT charger deliver to the battery at 95% efficiency?
Show the solution
- Energy delivered.
- In amp-hours. at 13.5 V.
- Compare with a direct connection. That would give about
Answer about 1136 Wh a day, or 84 Ah at 13.5 V.
Worked example
At the panel's 239 W peak, with the charger 95% efficient, how long does it take to put 50 Ah into the 13.5 V battery?
Show the solution
- Charging current.
- Time. of full sun.
- In a real day. The sun isn't full for long, so that's more like most of a day's harvest.
Answer about 3.0 hours of full sun.
Check
Model the panel, find its maximum power point, and write a perturb-and-observe tracker.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
A buck MPPT charger feeds a 13.5 V battery from a panel whose maximum power point is at 30 V. What duty cycle holds the panel at its peak?
Check
An MPPT charger with efficiency 0.93 holds a panel at its 240 W peak while charging a 26 V battery. What's the charging current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A panel's maximum power point is 30 V at 7.2 A, its open-circuit voltage 37.5 V and short-circuit current 8.2 A. What's its fill factor?
Check
A panel's maximum power point is 31.6 V at 5 A; its open-circuit voltage is 44 V and short-circuit current 9.5 A. A buck charger feeds a 12.8 V battery.
(a)
What is the fill factor?
(b)
What duty cycle holds the panel at its peak?
Check
A 239 W panel gets 3 full-sun-equivalent hours a day; its MPPT charger is 96% efficient into a 13.5 V battery.
(a)
What energy reaches the battery each day?
Write units the way you normally would: 1.5 Wh, 1500 mWh and 0.0015 kWh are the same answer.
(b)
How many amp-hours is that?
Explain why
Why does a solar charger need a DC-DC converter between the panel and the battery?
A solar panel delivers its maximum power only at one particular voltage, which changes with sunlight and temperature, while a battery holds its terminals at its own voltage, set by its chemistry and state of charge. Connected directly, the panel is forced to the battery's voltage, usually well below its peak, where it delivers roughly its short-circuit current at a low voltage and wastes much of its potential power. A converter decouples the two: by adjusting its duty cycle, it lets the panel run at its maximum power point while delivering that power to the battery at the battery's voltage and a correspondingly higher current. A tracking algorithm keeps adjusting the duty cycle as conditions change.
Practice
Keep practicing
7 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.