A buck MPPT charger feeds a 13.5 V battery from a panel whose maximum power point is at 30 V. What duty cycle holds the panel at its peak?
Check
An MPPT charger with efficiency 0.93 holds a panel at its 240 W peak while charging a 26 V battery. What's the charging current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A panel's maximum power point is 30 V at 7.2 A, its open-circuit voltage 37.5 V and short-circuit current 8.2 A. What's its fill factor?
Check
A panel's maximum power point is 31.6 V at 5 A; its open-circuit voltage is 44 V and short-circuit current 9.5 A. A buck charger feeds a 12.8 V battery.
(a)
What is the fill factor?
(b)
What duty cycle holds the panel at its peak?
Check
A 239 W panel gets 3 full-sun-equivalent hours a day; its MPPT charger is 96% efficient into a 13.5 V battery.
(a)
What energy reaches the battery each day?
Write units the way you normally would: 1.5 Wh, 1500 mWh and 0.0015 kWh are the same answer.
(b)
How many amp-hours is that?
Check
MPPT duty: 6 V battery, 60 V peak?
Check
Charge current: 10 W, η = 0.85, 48 V?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in D2