A digital PWM counts at 200 MHz for a buck switching at 250 kHz from 48 V.
(a)
How many duty steps per period?
(b)
What output step does each give?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A digital buck from 12 V at 200 kHz has an ADC step of 20 mV at the output.
(a)
What DPWM clock is needed to avoid limit cycles without dithering?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
(b)
With a 100 MHz counter, how many bits of dithering would close the gap?
Check
A digital loop samples once per 200 kHz period, computes in 0.5 µs and crosses over at 20 kHz.
(a)
How much phase does the delay cost?
Check
A 200-step DPWM on a 48 V buck adds a dither pattern lasting 2 to the power 2 periods.
(a)
How many effective steps result?
(b)
What effective output step?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A 100 MHz counter drives a PWM at 100 kHz.
(a)
How many bits of duty resolution is that?
Check
A loop samples at 100 kHz and computes in 3 µs. Its compensator was designed for 50° of margin ignoring delay, at a crossover of 100/10 kHz.
(a)
What margin remains?
Check
DPWM output step: 48 V, 200 kHz, 100 MHz?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
Delay phase at 15 kHz: 150 kHz sampling, 1 µs compute?
Check
Effective steps: 128 with 2 bits of dither?