S11 · Final exam
Final exam: power electronics
Twelve problems from the whole course: steady-state conversion and ripple, the converter family, losses and efficiency, DCM, isolated converters, small-signal models and loop design, input filters, current-mode control, magnetics, harmonics and rectifiers, PFC, inverters, resonant and soft-switched converters, thermal design, gate drives and EMI. Give yourself three hours and work without the lessons open. "Another set" deals a different exam.
Check
A buck from 24 V to 1.8 V with 10 µH and 22 µF at 500 kHz.
(a)
Duty cycle?
(b)
Inductor ripple, peak to peak?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(c)
Output ripple?
Check
A buck-boost (inverting) from 5 V at D = 0.4, delivering 4 A.
(a)
Output magnitude?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Average inductor current?
(c)
Switch voltage while off?
Check
A boost from 12 V at D = 0.4 with 100 mΩ of inductor resistance and a 30 Ω load.
(a)
Efficiency?
(b)
Output voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A buck from 12 V at D = 0.4: 1 µH, 100 kHz, 60 Ω.
(a)
K?
(b)
Output in DCM?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Isolated converters from 48 V with turns ratio 0.1 at D = 0.4.
(a)
Forward converter's output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Flyback's output?
Check
A boost at D = 0.3 with 10 µH, 220 µF and a 15 Ω load.
(a)
Resonant frequency of the small-signal model?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
RHP zero?
Check
A lead compensator with its zero at 2 kHz and pole at 20 kHz; a type III with zeros at 2 kHz and poles at 20 kHz evaluated at 15 kHz.
(a)
Maximum lead of the single zero–pole pair?
(b)
Type III phase at 15 kHz?
Check
A converter regulates 20 W from 28 V behind an LC filter of 47 µH and 100 µF.
(a)
Magnitude of its negative input resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Filter resonance?
Check
A current-mode boost from 5 V to 30 V with 22 µH.
(a)
Rising slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(b)
Minimum compensating slope?
Check
An inductor of 47 µH carrying 3 A peak, = 0.3 T, core 1.2 cm².
(a)
Turns (before rounding)?
(b)
Gap?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
A load draws a fundamental of 3 A at 35° lag from 120 V RMS, with THD 90%.
(a)
Real power?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Power factor?
Check
A six-pulse thyristor bridge on 480 V at α = 15° carrying 300 A with 0.4 mH of source inductance (60 Hz).
(a)
DC output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
5th-harmonic line current (RMS)?
Check
A boost PFC delivers 300 W from 120 V RMS (50 Hz) to a 400 V bus with 680 µF.
(a)
Emulated resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Bus ripple, peak to peak?
Check
A three-phase inverter on 400 V at m = 0.7, 2 µs dead time at 20 kHz.
(a)
Line-to-line RMS?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Dead-time voltage error?
Check
A half-bridge with 100 pF per switch on 400 V at 300 kHz; an inductor of 40 µH available to swing the node.
(a)
Capacitive loss per switch if hard-switched?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Current needed for ZVS?
Check
A switch dissipating 5 W ( = 1 K/W, pad 0.5 K/W) in 35 °C air; its switch node's edges take 5 ns.
(a)
Heat sink for a 110 °C junction?
Write units the way you normally would: 1.5 K/W and 1500 mK/W are the same answer.
(b)
Where does the switch node's spectrum begin falling 40 dB per decade?
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
16 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.