A buck from 24 V to 1.8 V with 10 µH and 22 µF at 500 kHz.
(a)
Duty cycle?
(b)
Inductor ripple, peak to peak?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(c)
Output ripple?
Check
A buck-boost (inverting) from 5 V at D = 0.4, delivering 4 A.
(a)
Output magnitude?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Average inductor current?
(c)
Switch voltage while off?
Check
A boost from 12 V at D = 0.4 with 100 mΩ of inductor resistance and a 30 Ω load.
(a)
Efficiency?
(b)
Output voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A buck from 12 V at D = 0.4: 1 µH, 100 kHz, 60 Ω.
(a)
K?
(b)
Output in DCM?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Isolated converters from 48 V with turns ratio 0.1 at D = 0.4.
(a)
Forward converter's output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Flyback's output?
Check
A boost at D = 0.3 with 10 µH, 220 µF and a 15 Ω load.
(a)
Resonant frequency of the small-signal model?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
RHP zero?
Check
A lead compensator with its zero at 2 kHz and pole at 20 kHz; a type III with zeros at 2 kHz and poles at 20 kHz evaluated at 15 kHz.
(a)
Maximum lead of the single zero–pole pair?
(b)
Type III phase at 15 kHz?
Check
A converter regulates 20 W from 28 V behind an LC filter of 47 µH and 100 µF.
(a)
Magnitude of its negative input resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Filter resonance?
Check
A current-mode boost from 5 V to 30 V with 22 µH.
(a)
Rising slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(b)
Minimum compensating slope?
Check
An inductor of 47 µH carrying 3 A peak, = 0.3 T, core 1.2 cm².
(a)
Turns (before rounding)?
(b)
Gap?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
A load draws a fundamental of 3 A at 35° lag from 120 V RMS, with THD 90%.
(a)
Real power?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Power factor?
Check
A six-pulse thyristor bridge on 480 V at α = 15° carrying 300 A with 0.4 mH of source inductance (60 Hz).
(a)
DC output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
5th-harmonic line current (RMS)?
Check
A boost PFC delivers 300 W from 120 V RMS (50 Hz) to a 400 V bus with 680 µF.
(a)
Emulated resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Bus ripple, peak to peak?
Check
A three-phase inverter on 400 V at m = 0.7, 2 µs dead time at 20 kHz.
(a)
Line-to-line RMS?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Dead-time voltage error?
Check
A half-bridge with 100 pF per switch on 400 V at 300 kHz; an inductor of 40 µH available to swing the node.
(a)
Capacitive loss per switch if hard-switched?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Current needed for ZVS?
Check
A switch dissipating 5 W ( = 1 K/W, pad 0.5 K/W) in 35 °C air; its switch node's edges take 5 ns.
(a)
Heat sink for a 110 °C junction?
Write units the way you normally would: 1.5 K/W and 1500 mK/W are the same answer.
(b)
Where does the switch node's spectrum begin falling 40 dB per decade?