S11 · Problem set 5
Problem set 5: peak current-mode control and slope compensation, magnetic circuits and losses, inductor design and transformer design
These problems cover lessons 23 to 26: inductor-current slopes, the perturbation factor α and the slope compensation that tames it, gapped cores, flux density, skin depth and core loss, the inductor design procedure, and transformer turns, loss optimization and window allocation.
Check
A current-mode buck from 12 V to 1.2 V with L = 10 µH.
(a)
Rising slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(b)
Falling slope?
(c)
α without compensation?
Check
A current-mode boost from 5 V to 30 V with L = 47 µH.
(a)
α without compensation?
(b)
Minimum compensating slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(c)
α with ?
Check
A current loop with α = −0.4; and a current-mode buck feeding 5 Ω with 330 µF.
(a)
Perturbation remaining after 4 cycles?
(b)
Voltage-loop plant pole?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A gap-dominated core: 10 turns, 0.3 mm gap, 150 mm², carrying 8 A peak.
(a)
Inductance?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
(b)
Peak flux density?
Check
Copper at 200 kHz; a ferrite with mW/cm³ (f in kHz) at 0.12 T, 4 cm³.
(a)
Skin depth?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
(b)
Core loss?
Check
An inductor of 15 µH, 4 A peak, = 0.3 T, core 1.4 cm².
(a)
Turns (before rounding)?
(b)
Gap?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
33 µH, 4 A peak, 8 A RMS, = 0.3 T, 0.5 W copper, = 0.35; a core with = 0.8 cm², = 1 cm², MLT = 4 cm.
(a)
Required ?
(b)
Core's ?
Check
12 turns filling the window ( = 0.5, = 2.5 cm²), MLT 5 cm, 4 A RMS.
(a)
Wire area?
(b)
Copper loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A forward transformer: 36 V at D = 0.3, 250 kHz, = 0.1 T, 0.4 cm².
(a)
Volt-seconds per pulse?
Write units the way you normally would: 1.5 µV·s, 1500 nV·s and 0.0015 mV·s are the same answer.
(b)
Primary turns (before rounding)?
Check
At the optimum a transformer's core loses 0.2 W with β = 2.6.
(a)
Copper loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Core loss if were cut to 0.8 of the optimum?
(c)
Copper loss then?
Check
A transformer: primary 8 turns at 1 A, secondary 4 turns at 12 A; 60 µV·s on a 10-turn winding on 0.5 cm².
(a)
Primary's window share?
(b)
Peak AC flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
An inductor (22 µH, 25 turns, 1.2 cm²) carrying 3 A peak.
(a)
Peak flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
(b)
Energy stored at the peak?
Check
A peak current-mode buck makes 5 V from 24 V with 10 µH and a compensating ramp of 0.75 times the falling slope.
(a)
What is α?
(b)
Over how many cycles does a current disturbance shrink a hundredfold?
Check
An inductor of 47 µH carries 2 A peak with = 0.3 T in a gap-dominated core.
(a)
How much energy does it store at peak?
Write units the way you normally would: 1.5 mJ, 1500 µJ and 0.0015 J are the same answer.
(b)
What gap volume must hold that energy?
Check
A winding at 100 kHz needs 1 mm² of copper, made of litz strands two skin depths in diameter.
(a)
What is the skin depth?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
(b)
How many strands of diameter 2δ does it take?
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.