S1128 of 55
0 XP
  1. Hook
  2. Problems

S11 · Problem set 5

Problem set 5: peak current-mode control and slope compensation, magnetic circuits and losses, inductor design and transformer design

These problems cover lessons 23 to 26: inductor-current slopes, the perturbation factor α and the slope compensation that tames it, gapped cores, flux density, skin depth and core loss, the Kg inductor design procedure, and transformer turns, loss optimization and window allocation.

Check

A current-mode buck from 12 V to 1.2 V with L = 10 µH.

(a)

Rising slope?

Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.

(b)

Falling slope?

(c)

α without compensation?

Check

A current-mode boost from 5 V to 30 V with L = 47 µH.

(a)

α without compensation?

(b)

Minimum compensating slope?

Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.

(c)

α with ma=m2/2?

Check

A current loop with α = −0.4; and a current-mode buck feeding 5 Ω with 330 µF.

(a)

Perturbation remaining after 4 cycles?

(b)

Voltage-loop plant pole?

Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.

Check

A gap-dominated core: 10 turns, 0.3 mm gap, 150 mm², carrying 8 A peak.

(a)

Inductance?

Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.

(b)

Peak flux density?

Check

Copper at 200 kHz; a ferrite with Pv=3f1.6B2.6 mW/cm³ (f in kHz) at 0.12 T, 4 cm³.

(a)

Skin depth?

Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.

(b)

Core loss?

Check

An inductor of 15 µH, 4 A peak, Bmax = 0.3 T, core 1.4 cm².

(a)

Turns (before rounding)?

(b)

Gap?

Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.

Check

33 µH, 4 A peak, 8 A RMS, Bmax = 0.3 T, 0.5 W copper, Ku = 0.35; a core with Ac = 0.8 cm², WA = 1 cm², MLT = 4 cm.

(a)

Required Kg?

(b)

Core's Kg?

Check

12 turns filling the window (Ku = 0.5, WA = 2.5 cm²), MLT 5 cm, 4 A RMS.

(a)

Wire area?

(b)

Copper loss?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

A forward transformer: 36 V at D = 0.3, 250 kHz, Bac = 0.1 T, 0.4 cm².

(a)

Volt-seconds per pulse?

Write units the way you normally would: 1.5 µV·s, 1500 nV·s and 0.0015 mV·s are the same answer.

(b)

Primary turns (before rounding)?

Check

At the optimum a transformer's core loses 0.2 W with β = 2.6.

(a)

Copper loss?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

(b)

Core loss if Bac were cut to 0.8 of the optimum?

(c)

Copper loss then?

Check

A transformer: primary 8 turns at 1 A, secondary 4 turns at 12 A; 60 µV·s on a 10-turn winding on 0.5 cm².

(a)

Primary's window share?

(b)

Peak AC flux density?

Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.

Check

An inductor (22 µH, 25 turns, 1.2 cm²) carrying 3 A peak.

(a)

Peak flux density?

Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.

(b)

Energy stored at the peak?

Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.

Practice

Keep practicing

15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.