S11 Power electronics · Practice
Problem set 5: current-mode control and magnetics
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A current-mode buck from 12 V to 1.2 V with L = 10 µH.
(a)
Rising slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(b)
Falling slope?
(c)
α without compensation?
Check
A current-mode boost from 5 V to 30 V with L = 47 µH.
(a)
α without compensation?
(b)
Minimum compensating slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(c)
α with ?
Check
A current loop with α = −0.4; and a current-mode buck feeding 5 Ω with 330 µF.
(a)
Perturbation remaining after 4 cycles?
(b)
Voltage-loop plant pole?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A gap-dominated core: 10 turns, 0.3 mm gap, 150 mm², carrying 8 A peak.
(a)
Inductance?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
(b)
Peak flux density?
Check
Copper at 200 kHz; a ferrite with mW/cm³ (f in kHz) at 0.12 T, 4 cm³.
(a)
Skin depth?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
(b)
Core loss?
Check
An inductor of 15 µH, 4 A peak, = 0.3 T, core 1.4 cm².
(a)
Turns (before rounding)?
(b)
Gap?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
33 µH, 4 A peak, 8 A RMS, = 0.3 T, 0.5 W copper, = 0.35; a core with = 0.8 cm², = 1 cm², MLT = 4 cm.
(a)
Required ?
(b)
Core's ?
Check
12 turns filling the window ( = 0.5, = 2.5 cm²), MLT 5 cm, 4 A RMS.
(a)
Wire area?
(b)
Copper loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A forward transformer: 36 V at D = 0.3, 250 kHz, = 0.1 T, 0.4 cm².
(a)
Volt-seconds per pulse?
Write units the way you normally would: 1.5 µV·s, 1500 nV·s and 0.0015 mV·s are the same answer.
(b)
Primary turns (before rounding)?
Check
At the optimum a transformer's core loses 0.2 W with β = 2.6.
(a)
Copper loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Core loss if were cut to 0.8 of the optimum?
(c)
Copper loss then?
Check
A transformer: primary 8 turns at 1 A, secondary 4 turns at 12 A; 60 µV·s on a 10-turn winding on 0.5 cm².
(a)
Primary's window share?
(b)
Peak AC flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
An inductor (22 µH, 25 turns, 1.2 cm²) carrying 3 A peak.
(a)
Peak flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
(b)
Energy stored at the peak?
Check
A peak current-mode buck makes 5 V from 24 V with 10 µH and a compensating ramp of 0.75 times the falling slope.
(a)
What is α?
(b)
Over how many cycles does a current disturbance shrink a hundredfold?
Check
An inductor of 47 µH carries 2 A peak with = 0.3 T in a gap-dominated core.
(a)
How much energy does it store at peak?
Write units the way you normally would: 1.5 mJ, 1500 µJ and 0.0015 J are the same answer.
(b)
What gap volume must hold that energy?
Check
A winding at 100 kHz needs 1 mm² of copper, made of litz strands two skin depths in diameter.
(a)
What is the skin depth?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
(b)
How many strands of diameter 2δ does it take?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S11