S11 Power electronics · Practice
Problem set 7: space vectors, grid inverters and multilevel converters
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A space-vector reference of index 0.6 sits 12° into its sector, with a 125 µs switching period.
(a)
How long is the first active vector applied?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
(b)
And the second?
(c)
How much time do the zero vectors share?
Check
A space-vector reference of index 0.5 points at 130° (sector 1 runs from 0° to 60°), with a 100 µs period.
(a)
Which sector is it in?
(b)
How long is the sector's second active vector applied?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
Check
A motor is rated 400 V line to line; its drive's bus needs 5% margin over the minimum.
(a)
What bus voltage does space-vector modulation need?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
And sinusoidal PWM?
(c)
And six-step, where the line-to-line fundamental is ?
Check
An inverter on a 650 V bus must produce 300 V line to line.
(a)
What space-vector modulation index does it need?
(b)
What sinusoidal PWM index would it need?
Check
A drive's switches lose 120 W in switching at 8 kHz with continuous space-vector modulation; switching loss is 0.65 of the total semiconductor loss.
(a)
What switching loss does discontinuous PWM leave at the same carrier frequency?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What total semiconductor loss results?
(c)
Alternatively, what carrier frequency would discontinuous PWM allow for the original switching loss?
Check
A grid inverter on a 480 V, 50 Hz line supplies 10 kW and 8 kvar through 3 mH per phase.
(a)
What current does each phase carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What phase voltage must the bridge make?
(c)
What is the least DC link that space-vector modulation can do it with?
Check
An LCL filter has = 1 mH, = 0.3 mH and C = 15 µF; its inverter switches at 20 kHz.
(a)
Where is its resonance?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
How much better than a single inductor of the same total does it attenuate the switching frequency (undamped, stiff grid)?
(c)
What series damping resistor equals a third of the capacitor's reactance at resonance?
Check
An LCL filter with = 2 mH and = 0.25 mH must resonate between ten times the 60 Hz grid frequency and half the 16 kHz switching frequency.
(a)
What is the largest capacitance allowed?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
(b)
And the smallest?
Check
A 30 kVA grid inverter on 400 V, 60 Hz has filter capacitors of 20 µF per phase, connected line to neutral.
(a)
How much reactive power do the capacitors draw?
Write units the way you normally would: 1.5 kvar, 1500 var and 0.0015 Mvar are the same answer.
(b)
What percentage of the rating is that? (Designs usually keep it under 5%.)
Check
An inverter's bridge puts 80 V RMS of ripple at its 10 kHz switching frequency into an LCL filter with = 2 mH, = 1 mH and C = 10 µF, feeding a stiff grid; its rated current is 20 A.
(a)
What ripple current reaches the grid?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What percentage of rated current is that? (Grid codes typically allow 0.3% at these frequencies.)
Check
An inverter rated 20 kVA supplies real power at 0.5 of its rating.
(a)
How much reactive power can it add?
Write units the way you normally would: 1.5 kvar, 1500 var and 0.0015 Mvar are the same answer.
(b)
At what power factor is it then running?
Check
A cascaded H-bridge drive for a 6.6 kV motor uses 640 V cells switching at 500 Hz with unipolar PWM and phase-shifted carriers.
(a)
How many cells per phase?
(b)
How many levels does the line-to-line voltage have?
(c)
At what frequency does the output ripple appear?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A diode-clamped inverter with 3 levels runs from a 1500 V bus, with 300 ns switching edges.
(a)
What does each switch block?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What dv/dt does the motor cable see?
Check
An MMC's DC link is 320 kV pole to pole, built from 1.6 kV submodules, each with 15 mF of capacitance.
(a)
How many submodules does each arm need at least?
(b)
How much energy do all six arms' capacitors store?
Write units the way you normally would: 1.5 MJ, 1500 kJ and 0.0015 GJ are the same answer.
Check
A drive runs a motor in six-step from a 650 V bus at 50 Hz; the motor's leakage inductance is 5 mH per phase.
(a)
What is the phase voltage's 5th harmonic, RMS? (The fundamental is .)
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What 5th harmonic current does it drive through the leakage inductance?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S11