S11 Power electronics · Practice
Problem set 9: reliability, capacitors and solar converters
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
An electrolytic rated 5000 h at 85 °C sits in 70 °C air and carries 2.5 A RMS of ripple through 30 mΩ of ESR, with 12 K/W from core to air.
(a)
What is its core temperature?
(b)
What life should it have?
Check
An electrolytic rated 3000 h at 105 °C runs at 50 °C for 0.6 of its life and at 100 °C for the rest.
(a)
What life does Miner's rule give?
(b)
What percentage of the wear happens in the hot periods?
Check
A converter has 30 small parts at 2 FIT, 8 power devices at 100 FIT and 1 electrolytics at 150 FIT.
(a)
What is its failure rate?
(b)
What is its MTBF?
(c)
What percentage fail within ten years of continuous use?
Check
A qualification test runs parts at 150 °C for 2000 hours. The failure mechanism has an activation energy of 0.7 eV; in the field the parts run at 40 °C.
(a)
What is the acceleration factor?
(b)
How many years of field use does the test represent?
Check
A rail needs 47 µF of effective capacitance. Its 22 µF X5R ceramics keep 0.35 of their capacitance at the working bias and 0.9 at the operating temperature.
(a)
How much nominal capacitance is needed?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
(b)
How many parts?
Check
A DC link carries 6 A RMS of ripple; its capacitors are each rated 1.2 A RMS at the frequency and temperature of use, with 90 mΩ of ESR.
(a)
How many in parallel does the ripple rating require?
(b)
What do they dissipate in total?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Modules with = 41 V at 25 °C (rising 0.27% per kelvin of cooling) go into strings for an inverter limited to 1500 V; the site's coldest morning is 40 K below 25 °C.
(a)
What is a module's coldest open-circuit voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
How many modules can a string have?
Check
An inverter tracks the maximum power point only above 550 V. Its modules have = 34 V at 25 °C, falling 0.35% per kelvin, and run 45 K hotter on summer afternoons.
(a)
What is a module's hot ?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is the fewest modules a string can have?
Check
An array of 2 strings of 16 modules, each 450 W at 25 °C and full sun, runs 20 K hotter in 0.6 of full sun; power falls 0.4% per kelvin.
(a)
What does the array deliver?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
Check
A boost stage holds 2 module(s) in series, each at 30 V and 400 W at its MPP, and feeds a 400 V bus.
(a)
What duty cycle does it run at?
(b)
What current does its inductor carry on average?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A tracker measures 7 A at 26 V with an incremental conductance of −0.6 S.
(a)
What is dP/dV?
Write units the way you normally would: 1.5 W/V, 1500 mW/V and 0.0015 kW/V are the same answer.
(b)
What incremental conductance would mark the MPP at this operating point?
Check
A module delivers 350 W at its MPP, with = 38 V and = 11 A.
(a)
What is its fill factor?
Check
A 60-cell module has three bypass diodes, one across each group of 20 cells; its is 30 V. One cell in a string of 12 such modules is shaded, so its group is bypassed through a diode dropping 0.7 V.
(a)
What MPP voltage does the string now have (taking the unshaded groups' voltage as unchanged)?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What percentage of the string's power is lost, at unchanged current?
Check
A device dissipates 10 W through 0.8 K/W (junction to sink) and a 0.8 K/W heat sink into 50 °C air. Its dominant failure mechanism has an activation energy of 0.6 eV.
(a)
What is its junction temperature?
(b)
How many times faster does it fail than with a heat sink of half the resistance?
Check
A product with a failure rate of 300 FIT is in service in 20000 units, each running 16 hours a day.
(a)
How many field failures should the fleet see per year?
(b)
What percentage of the units fail randomly over a ten-year service life?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S11