S11 · Lesson 26 · Transformer design
Choosing turns from the applied volt-seconds, the trade-off between core loss and copper loss and the flux density that minimizes their sum, allocating the window among windings, and leakage inductance
A transformer in a switching converter isn't limited by saturation from DC current the way an inductor is, since its windings' ampere-turns largely cancel. It's limited by loss. Fewer turns mean less copper but a larger flux swing and more core loss; more turns mean the reverse. Somewhere between lies a flux density that minimizes the total, and finding it, then splitting the window among the windings in proportion to the current each carries, is transformer design.
- The core loss, copper loss and total loss of a transformer against the peak AC flux density , for a core whose loss goes as and copper whose loss goes as (fewer turns at higher B).
- The total has a minimum where the copper loss is = 1.35 times the core loss.
- The sliders scale the two loss coefficients, as a bigger window (less copper loss) or a lower frequency (less core loss) would; the optimum moves accordingly.
Predict
A forward converter applies 48 V to its transformer's primary for 40% of a 5 µs period. With a 0.5 cm² core and a peak AC flux density of 0.1 T, how many primary turns are needed?
The applied volt-seconds are λ = 48 × 0.4 × 5 µs = 96 µV·s, which swings the flux by , twice the peak AC value: = 96 µV·s/(2 × 0.1 × 0.5 × 10⁻⁴) = 9.6, so 10 turns. Load current doesn't enter: the primary and secondary ampere-turns cancel.
Name it
Turns from volt-seconds
By Faraday's law, applying volt-seconds λ to an N-turn winding swings the core flux density by . With the peak AC flux density:
Other windings follow from the turns ratios.
Loss trade-off
Core loss goes as (Steinmetz, β ≈ 2.6 to 2.8). For a fixed window, turns go as and wire area as , so copper loss goes as . Minimizing the sum gives
at the optimum: slightly more copper loss than core loss.
Window allocation
Give each winding a share of the window in proportion to its share of the total RMS ampere-turns, . That equalizes current density and minimizes total copper loss.
Leakage inductance
Flux that links one winding but not another appears as leakage inductance in series, causing voltage spikes at turn-off in flybacks and limiting how fast current can transfer between windings. Interleaving the windings (primary, secondary, primary) cuts it.
Worked example
Design the forward converter's transformer: 48 V, D = 0.4, 200 kHz, 0.5 cm² core, 5 V out.
Show the solution
- Volt-seconds.
- Flux swing with 12 primary turns.
- Turns ratio. For 5 V from 48 V × 0.4 × n: so 3 secondary turns (n = 0.25, D = 0.42 at nominal).
- Window split. With a 4.8 A secondary and a 1.2 A primary, the ampere-turns are equal: so each winding gets half the window.
Answer 12 primary turns (0.08 T) and 3 secondary turns, with each winding getting half the window.
Worked example
A core loses 20 W and the copper 0.0004/ W. Find the optimum.
Show the solution
- Set the derivative of the total to zero.
- Losses there. The ratio is 1.35 = β/2, and the total is 0.079 W.
- Away from the optimum. Halving from the optimum would cut core loss by = 6.5 times but quadruple copper loss.
Answer the optimum is = 0.094 T, where the core loses 0.034 W and the copper 0.045 W, 0.079 W in all.
Worked example
A forward converter makes 5 V at 20 A from 48 V at D = 0.4. What turns ratio does it need, and what RMS currents do its windings carry (ignoring magnetizing current and ripple)?
Show the solution
- Turns ratio.
- On-time currents. During the on-time the secondary carries the 20 A load and the primary
- RMS currents. Each conducts for 40% of the period:
- Sizing the windings. Winding areas are sized for these RMS values rather than the averages.
Answer n = 0.260; the secondary carries 12.6 A RMS and the primary 3.29 A RMS.
Check
A forward converter applies 48 V to its primary at D = 0.3 and 300 kHz. What volt-seconds does each pulse apply?
Write units the way you normally would: 1.5 µV·s, 1500 nV·s and 0.0015 mV·s are the same answer.
Check
A winding receives 100 µV·s per pulse on a 1.5 cm² core, with peak AC flux density 0.05 T. How many turns does it need (before rounding)?
Check
A winding of 8 turns on a 1 cm² core receives 50 µV·s per pulse. What's the peak AC flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
At its optimal flux density, a transformer's core loss is 0.5 W with Steinmetz exponent β = 2.6. What's the total loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A transformer's primary has 10 turns at 0.5 A RMS and its secondary 5 turns at 8 A RMS. What fraction of the window should the primary get?
Check
If a transformer's peak AC flux density is cut to 0.7 of its value, by what factor does its core loss change (β = 2.6)?
Check
A forward converter makes 3.3 V at 20 A from 48 V at D = 0.4.
(a)
What turns ratio ?
(b)
What RMS current does the secondary carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(c)
And the primary?
Check
A winding of N turns on core area A receives V volts for D of each period at frequency f.
Step 1
What volt-seconds per pulse?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What flux swing ΔB?
Step 3
What peak AC flux density?
Explain why
Why doesn't a forward converter's transformer saturate from its load current the way an inductor would?
In a transformer the load current flows in the secondary and an almost equal and opposite current, scaled by the turns ratio, flows in the primary, so their magnetomotive forces cancel and the load current produces essentially no net flux in the core. The only flux comes from the magnetizing current, set by the volt-seconds applied to the winding, independent of the load. So a transformer's core is sized by the applied voltage, frequency and loss, while an inductor's is sized by the current it carries, because in an inductor the entire current produces flux and the energy it stores must fit in the core and gap.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.