S1126 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S11 · Lesson 26 · Transformer design

Choosing turns from the applied volt-seconds, the trade-off between core loss and copper loss and the flux density that minimizes their sum, allocating the window among windings, and leakage inductance

A transformer in a switching converter isn't limited by saturation from DC current the way an inductor is, since its windings' ampere-turns largely cancel. It's limited by loss. Fewer turns mean less copper but a larger flux swing and more core loss; more turns mean the reverse. Somewhere between lies a flux density that minimizes the total, and finding it, then splitting the window among the windings in proportion to the current each carries, is transformer design.

  • The core loss, copper loss and total loss of a transformer against the peak AC flux density Bac, for a core whose loss goes as B2.7 and copper whose loss goes as 1/B2 (fewer turns at higher B).
  • The total has a minimum where the copper loss is β/2 = 1.35 times the core loss.
  • The sliders scale the two loss coefficients, as a bigger window (less copper loss) or a lower frequency (less core loss) would; the optimum moves accordingly.

Predict

A forward converter applies 48 V to its transformer's primary for 40% of a 5 µs period. With a 0.5 cm² core and a peak AC flux density of 0.1 T, how many primary turns are needed?

Name it

Turns from volt-seconds

By Faraday's law, applying volt-seconds λ to an N-turn winding swings the core flux density by ΔB=λ/NAc. With Bac=ΔB/2 the peak AC flux density:

N1=λ12BacAc,λ1=V1ton

Other windings follow from the turns ratios.

Loss trade-off

Core loss goes as Bacβ (Steinmetz, β ≈ 2.6 to 2.8). For a fixed window, turns go as 1/Bac and wire area as Bac, so copper loss goes as 1/Bac2. Minimizing the sum gives

Pcu=β2Pfe

at the optimum: slightly more copper loss than core loss.

Window allocation

Give each winding a share of the window in proportion to its share of the total RMS ampere-turns, αk=NkIk∑NjIj. That equalizes current density and minimizes total copper loss.

Leakage inductance

Flux that links one winding but not another appears as leakage inductance in series, causing voltage spikes at turn-off in flybacks and limiting how fast current can transfer between windings. Interleaving the windings (primary, secondary, primary) cuts it.

Worked example

Design the forward converter's transformer: 48 V, D = 0.4, 200 kHz, 0.5 cm² core, 5 V out.

Show the solution
  1. Volt-seconds. λ=96μV·s
  2. Flux swing with 12 primary turns. Bac=96μV·s2×12×0.5cm2=0.08T
  3. Turns ratio. For 5 V from 48 V × 0.4 × n: n=548×0.4=0.26 so 3 secondary turns (n = 0.25, D = 0.42 at nominal).
  4. Window split. With a 4.8 A secondary and a 1.2 A primary, the ampere-turns are equal: 3×4.8A=14.4A=12×1.2A so each winding gets half the window.

Answer 12 primary turns (0.08 T) and 3 secondary turns, with each winding getting half the window.

Worked example

A core loses 20 Bac2.7 W and the copper 0.0004/Bac2 W. Find the optimum.

Show the solution
  1. Set the derivative of the total to zero. Bac4.7=2×0.00042.7×20Bac=0.094T
  2. Losses there. Pfe=20×0.0942.7=0.034WPcu=0.0004/0.0942=0.045W The ratio is 1.35 = β/2, and the total is 0.079 W.
  3. Away from the optimum. Halving Bac from the optimum would cut core loss by 22.7 = 6.5 times but quadruple copper loss.

Answer the optimum is Bac = 0.094 T, where the core loses 0.034 W and the copper 0.045 W, 0.079 W in all.

Worked example

A forward converter makes 5 V at 20 A from 48 V at D = 0.4. What turns ratio does it need, and what RMS currents do its windings carry (ignoring magnetizing current and ripple)?

Show the solution
  1. Turns ratio. n=50.4×48=0.260
  2. On-time currents. During the on-time the secondary carries the 20 A load and the primary Ip=n×20A=5.21A
  3. RMS currents. Each conducts for 40% of the period: Is,rms=200.4=12.6AIp,rms=nIs,rms=3.29A
  4. Sizing the windings. Winding areas are sized for these RMS values rather than the averages.

Answer n = 0.260; the secondary carries 12.6 A RMS and the primary 3.29 A RMS.

Check

A forward converter applies 48 V to its primary at D = 0.3 and 300 kHz. What volt-seconds does each pulse apply?

Write units the way you normally would: 1.5 µV·s, 1500 nV·s and 0.0015 mV·s are the same answer.

Check

A winding receives 100 µV·s per pulse on a 1.5 cm² core, with peak AC flux density 0.05 T. How many turns does it need (before rounding)?

Check

A winding of 8 turns on a 1 cm² core receives 50 µV·s per pulse. What's the peak AC flux density?

Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.

Check

At its optimal flux density, a transformer's core loss is 0.5 W with Steinmetz exponent β = 2.6. What's the total loss?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

A transformer's primary has 10 turns at 0.5 A RMS and its secondary 5 turns at 8 A RMS. What fraction of the window should the primary get?

Check

If a transformer's peak AC flux density is cut to 0.7 of its value, by what factor does its core loss change (β = 2.6)?

Check

A forward converter makes 3.3 V at 20 A from 48 V at D = 0.4.

(a)

What turns ratio Ns/Np?

(b)

What RMS current does the secondary carry?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(c)

And the primary?

Check

A winding of N turns on core area A receives V volts for D of each period at frequency f.

Step 1

What volt-seconds per pulse?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why doesn't a forward converter's transformer saturate from its load current the way an inductor would?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.