S11 Power electronics · Practice
Transformer design
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A forward converter applies 48 V to its primary at D = 0.3 and 300 kHz. What volt-seconds does each pulse apply?
Write units the way you normally would: 1.5 µV·s, 1500 nV·s and 0.0015 mV·s are the same answer.
Check
A winding receives 100 µV·s per pulse on a 1.5 cm² core, with peak AC flux density 0.05 T. How many turns does it need (before rounding)?
Check
A winding of 8 turns on a 1 cm² core receives 50 µV·s per pulse. What's the peak AC flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
At its optimal flux density, a transformer's core loss is 0.5 W with Steinmetz exponent β = 2.6. What's the total loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A transformer's primary has 10 turns at 0.5 A RMS and its secondary 5 turns at 8 A RMS. What fraction of the window should the primary get?
Check
If a transformer's peak AC flux density is cut to 0.7 of its value, by what factor does its core loss change (β = 2.6)?
Check
A forward converter makes 3.3 V at 20 A from 48 V at D = 0.4.
(a)
What turns ratio ?
(b)
What RMS current does the secondary carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(c)
And the primary?
Check
Volt-seconds: 24 V, D = 0.25, 500 kHz?
Write units the way you normally would: 1.5 µV·s, 1500 nV·s and 0.0015 mV·s are the same answer.
Check
Turns for 40 µV·s, = 0.06 T, 2 cm²?
Check
Primary's window share: 6 turns × 1 A against 6 turns × 15 A?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S11