S12 · Final exam
Final exam: electric machines
Twelve problems from the whole course: energy conversion and magnetics, transformers, windings and rotating fields, synchronous machines in steady state and transients, induction machines from slip to speed control, DC, permanent-magnet, reluctance and single-phase motors, dq models, field-oriented and PM motor control, and ratings. Give yourself three hours and work without the lessons open. "Another set" deals a different exam.
Check
A linear machine: 48 V, 0.2 Ω, 1 m bar, 0.4 T, 4 N load.
(a)
Current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Speed?
Check
NdFeB ( = 1.15 T at 25 °C, −0.12%/K, = 1.04), 9 mm long, facing a 1.4 mm gap of equal area, at 80 °C.
(a)
Gap flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
(b)
Maximum energy product at that temperature?
Check
A 30 kVA transformer: 100 W core, 2000 W full-load copper, power factor 1.
(a)
Load of peak efficiency?
(b)
Peak efficiency?
Check
An electromagnet (250 turns, 0.5 A, two 2 mm gaps of 8 cm²); a reluctance rotor with = 10 mH carrying 2 A.
(a)
Electromagnet force?
Write units the way you normally would: 1.5 N, 1500 mN and 0.0015 kN are the same answer.
(b)
Peak reluctance torque?
Check
A 6-pole, 60 Hz winding with q = 2 and pitch 0.8.
(a)
Winding factor?
(b)
Synchronous speed?
Check
A 400 MVA round-rotor generator ( = 0.8 pu) delivers 0.6 pu at power factor 0.95 lagging.
(a)
?
(b)
δ?
(c)
Reactive power delivered?
Write units the way you normally would: 1.5 Mvar, 1500 kvar and 0.0015 Gvar are the same answer.
Check
A salient-pole generator ( = 0.9, = 0.55 pu) delivers 1 pu at power factor 0.9 lagging on a 1 pu bus.
(a)
δ?
(b)
?
Check
A 4-pole, 50 Hz induction motor at slip 0.04 develops 60 kW of mechanical power.
(a)
Torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Rotor copper loss?
Check
Thévenin 150 V, = 0.15, = 1.6, = 0.25 Ω, = 125.7 rad/s.
(a)
Breakdown torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Starting torque?
Check
A motor starts direct on line at 5.5 times rated current and 1.4 times rated torque.
(a)
Line current with an autotransformer at tap 0.8?
(b)
Starting torque with a soft starter at 0.7 voltage?
Check
A separately excited DC motor (240 V, = 1.5, = 0.3 Ω) at 80 A.
(a)
Speed?
(b)
Starting resistance for 100 A?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A PM DC motor (12 V, R = 0.15 Ω, K = 0.08); a brushless motor rated 1200 rpm/V.
(a)
PM motor's peak power?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Brushless torque at 10 A?
Check
A switched reluctance motor (3 phases, 6 teeth, 15 A, 20 to 60 mH); a hybrid stepper with 50 teeth at 500 steps/s.
(a)
SRM average torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Stepper speed?
Check
A single-phase 4-pole, 60 Hz motor at slip 0.07: 2.5 A, = 9, = 1.4 Ω; standstill windings main 2 + j4, auxiliary 3 + j2 Ω.
(a)
Torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Capacitor reactance for a 90° split?
Check
A machine with = 0.1, = 1.2, = 0.3, = 0.07 pu; balanced currents of 10 A peak leading the d axis by 15°.
(a)
?
(b)
?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
An interior PM motor (6 poles, = 0.06 Wb, = 0.25 mH, = 0.8 mH, 120 A); a surface PM motor with the same , L = 0.3 mH, 150 V peak phase, = 120 A.
(a)
Interior motor's MTPA ?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Surface motor's base speed (6 poles)?
Check
A duty cycle of 120 N·m for 4 s and 70 N·m for 50 s; a winding 5 K hotter than designed; an 11 kW motor at 0.75 load for 4000 h a year, efficiency 0.9 raised by 0.025.
(a)
RMS torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Insulation life factor?
(c)
Energy saved per year?
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
17 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.