S12 Electric machines · Practice
Final exam
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A linear machine: 48 V, 0.2 Ω, 1 m bar, 0.4 T, 4 N load.
(a)
Current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Speed?
Check
NdFeB ( = 1.15 T at 25 °C, −0.12%/K, = 1.04), 9 mm long, facing a 1.4 mm gap of equal area, at 80 °C.
(a)
Gap flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
(b)
Maximum energy product at that temperature?
Check
A 30 kVA transformer: 100 W core, 2000 W full-load copper, power factor 1.
(a)
Load of peak efficiency?
(b)
Peak efficiency?
Check
An electromagnet (250 turns, 0.5 A, two 2 mm gaps of 8 cm²); a reluctance rotor with = 10 mH carrying 2 A.
(a)
Electromagnet force?
Write units the way you normally would: 1.5 N, 1500 mN and 0.0015 kN are the same answer.
(b)
Peak reluctance torque?
Check
A 6-pole, 60 Hz winding with q = 2 and pitch 0.8.
(a)
Winding factor?
(b)
Synchronous speed?
Check
A 400 MVA round-rotor generator ( = 0.8 pu) delivers 0.6 pu at power factor 0.95 lagging.
(a)
?
(b)
δ?
(c)
Reactive power delivered?
Write units the way you normally would: 1.5 Mvar, 1500 kvar and 0.0015 Gvar are the same answer.
Check
A salient-pole generator ( = 0.9, = 0.55 pu) delivers 1 pu at power factor 0.9 lagging on a 1 pu bus.
(a)
δ?
(b)
?
Check
A 4-pole, 50 Hz induction motor at slip 0.04 develops 60 kW of mechanical power.
(a)
Torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Rotor copper loss?
Check
Thévenin 150 V, = 0.15, = 1.6, = 0.25 Ω, = 125.7 rad/s.
(a)
Breakdown torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Starting torque?
Check
A motor starts direct on line at 5.5 times rated current and 1.4 times rated torque.
(a)
Line current with an autotransformer at tap 0.8?
(b)
Starting torque with a soft starter at 0.7 voltage?
Check
A separately excited DC motor (240 V, = 1.5, = 0.3 Ω) at 80 A.
(a)
Speed?
(b)
Starting resistance for 100 A?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A PM DC motor (12 V, R = 0.15 Ω, K = 0.08); a brushless motor rated 1200 rpm/V.
(a)
PM motor's peak power?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Brushless torque at 10 A?
Check
A switched reluctance motor (3 phases, 6 teeth, 15 A, 20 to 60 mH); a hybrid stepper with 50 teeth at 500 steps/s.
(a)
SRM average torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Stepper speed?
Check
A single-phase 4-pole, 60 Hz motor at slip 0.07: 2.5 A, = 9, = 1.4 Ω; standstill windings main 2 + j4, auxiliary 3 + j2 Ω.
(a)
Torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Capacitor reactance for a 90° split?
Check
A machine with = 0.1, = 1.2, = 0.3, = 0.07 pu; balanced currents of 10 A peak leading the d axis by 15°.
(a)
?
(b)
?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
An interior PM motor (6 poles, = 0.06 Wb, = 0.25 mH, = 0.8 mH, 120 A); a surface PM motor with the same , L = 0.3 mH, 150 V peak phase, = 120 A.
(a)
Interior motor's MTPA ?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Surface motor's base speed (6 poles)?
Check
A duty cycle of 120 N·m for 4 s and 70 N·m for 50 s; a winding 5 K hotter than designed; an 11 kW motor at 0.75 load for 4000 h a year, efficiency 0.9 raised by 0.025.
(a)
RMS torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Insulation life factor?
(c)
Energy saved per year?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12