S12 · Lesson 46 · Losses, heating and ratings
Where a machine's losses come from, efficiency and the energy cost of a few percent, measuring winding temperature by resistance, insulation classes and the halving of insulation life every 10 K, thermal time constants, and rating a motor for an intermittent duty cycle by its RMS torque
A motor's nameplate rating isn't a property of its electromagnetics. The same machine could deliver much more torque for a few seconds; what limits it is heat. Losses raise the temperature of the windings until their insulation degrades, and insulation ages roughly twice as fast for every 10 K it runs hotter. Ratings, efficiency standards and the choice of a motor for a duty cycle all follow from that chain: losses, temperature, insulation life.
- Expected insulation life against winding hot-spot temperature, using the rule that life halves for every 10 K (log scale), for an insulation class rated for 20,000 hours at its class temperature.
- Running 10 K over the class temperature halves the life; running 10 K under doubles it.
- Choose the class: B (130 °C), F (155 °C) or H (180 °C). Many motors use class F insulation but are designed for class B temperature rise, for a large margin.
Predict
A motor normally runs its windings at 120 °C. A blocked cooling fan raises them to 140 °C. What happens to its expected insulation life?
By the 10 K rule, each 10 K halves the life, so 20 K divides it by 4. The rule is approximate (it comes from the Arrhenius law of B11, with the activation energy of typical insulation), but it explains why ratings and temperature limits are taken so seriously.
Name it
Losses
- Stator copper and rotor copper ( in an induction machine), growing with load squared.
- Core loss, hysteresis and eddy currents (lesson 2), nearly constant at fixed voltage and frequency.
- Friction and windage, nearly constant at fixed speed.
- Stray load loss, from leakage fields and harmonics, roughly 0.5 to 2% of output, also growing with load.
Efficiency is output over output plus all losses. Standards (IEC 60034-30-1's IE1 to IE4 classes, NEMA Premium) set minimum efficiencies by rating and pole count.
Temperature
Winding temperature is measured by the rise in its copper resistance:
The machine heats roughly as a first-order system, , with a thermal time constant of minutes to hours.
Insulation and life
Insulation classes set the maximum hot-spot temperature: B 130 °C, F 155 °C, H 180 °C. Life roughly halves for every 10 K above it: relative life .
Duty cycles
For a load that varies faster than the thermal time constant, copper loss follows the square of current, roughly the square of torque, so a motor is sized by the RMS torque over the cycle, , with its peak torque checked separately against the breakdown or current limit.
Worked example
A winding's resistance rises from its 25 °C value by a factor of 1.32 after a heat run. What's its average temperature?
Show the solution
- Average temperature.
- Hot spot. The hot spot, usually 5 to 15 K above the average, is what the insulation class limits.
Answer the winding averages 108.0 °C.
Worked example
An 11 kW motor runs at 75% load for 6000 hours a year. How much energy does raising its efficiency from 90% to 93% save?
Show the solution
- Energy out. Output 8.25 kW for 6000 h is 49,500 kWh.
- Energy saved. a year, about 266 dollars at 15 cents per kWh.
- Over the motor's life. Over a 15-year life the saving is several times the price difference between efficiency classes.
Answer it saves 1774 kWh a year, about 266 dollars.
Worked example
A motor's duty cycle repeats every minute: 40 N·m for 10 s, 15 N·m for 20 s and 5 N·m for 30 s. What continuous torque rating does it need?
Show the solution
- Why RMS torque. Copper loss follows torque squared, so the motor heats as if it carried the RMS torque continuously.
- Mean square torque.
- RMS torque.
- Rating. A motor rated about 19 N·m continuous will run at its rated temperature, provided the one-minute cycle is much shorter than its thermal time constant and its peak torque, at least 40 N·m, is comfortably below breakdown.
- Sizing by the peak. Sizing by the 40 N·m peak would buy a motor twice as large.
Answer about 19 N·m continuous, since the RMS torque is 18.8 N·m, as long as the motor can also deliver the 40 N·m peak.
Check
A copper winding's resistance is 1.3 times its value at 20 °C. What's its temperature?
Check
A winding runs 10 K hotter than before. By what factor does its expected insulation life change?
Check
A motor's duty cycle is 150 N·m for 5 s, then 50 N·m for 60 s, repeating. What continuous torque rating does it need, thermally?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A 30 kW motor runs at 0.6 load for 8000 hours a year. Its efficiency rises from 0.92 by 0.02. How much energy is saved per year?
Write units the way you normally would: 1.5 kWh, 1500 Wh and 0.0015 MWh are the same answer.
Check
A 50 kW motor's losses are 2% (stator and rotor copper), 3% (core, friction, windage) and 1.5% (stray), all as percentages of output. What's its efficiency?
Check
A motor's steady temperature rise at its load is 80 K and its thermal time constant 45 min. How much has it risen after 10 min from cold?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
Check
A winding's resistance rises by a factor of 1.35 from its value at 25 °C. Its insulation is rated 155 °C; separately, consider a hot spot of 120 °C.
(a)
What is the winding's average temperature?
(b)
What relative life does a 120 °C hot spot give the insulation?
Check
A motor carries torque a for t seconds, then b for u seconds, repeatedly.
Step 1
What is its RMS torque?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is its average torque?
Explain why
Why is a motor for an intermittent load sized by RMS torque rather than peak or average torque?
What limits a motor's continuous rating is the temperature of its windings, and that's set by the average power lost, mainly copper loss, which grows with the square of current and so roughly with the square of torque. When the load cycles faster than the motor's thermal time constant, the windings respond to the time average of that loss, which is proportional to the mean of the squared torque: the RMS torque squared. An average of the torque itself would understate the heating, since the peaks contribute disproportionately. The peak torque still has to be checked separately, against the motor's breakdown torque or the drive's current limit, since it's an instantaneous constraint and not a thermal one.