Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A copper winding's resistance is 1.3 times its value at 20 °C. What's its temperature?
Check
A winding runs 10 K hotter than before. By what factor does its expected insulation life change?
Check
A motor's duty cycle is 150 N·m for 5 s, then 50 N·m for 60 s, repeating. What continuous torque rating does it need, thermally?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A 30 kW motor runs at 0.6 load for 8000 hours a year. Its efficiency rises from 0.92 by 0.02. How much energy is saved per year?
Write units the way you normally would: 1.5 kWh, 1500 Wh and 0.0015 MWh are the same answer.
Check
A 50 kW motor's losses are 2% (stator and rotor copper), 3% (core, friction, windage) and 1.5% (stray), all as percentages of output. What's its efficiency?
Check
A motor's steady temperature rise at its load is 80 K and its thermal time constant 45 min. How much has it risen after 10 min from cold?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
Check
A winding's resistance rises by a factor of 1.35 from its value at 25 °C. Its insulation is rated 155 °C; separately, consider a hot spot of 120 °C.
(a)
What is the winding's average temperature?
(b)
What relative life does a 120 °C hot spot give the insulation?
Check
Temperature: R ratio 1.1, from 15 °C?
Check
RMS torque: 50 N·m for 2 s, 100 N·m for 80 s?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
Life factor for 8 K hotter?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12