S122 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S12 · Lesson 2 · Magnetic materials and permanent magnets

Saturation and hysteresis in electrical steel, separating core loss into hysteresis and eddy-current parts, laminations, permanent magnets in the second quadrant, the load line set by the air gap, the maximum energy product and the least magnet volume, and temperature effects

A machine's iron carries its flux and its magnets create it. Steel is cheap and carries more than a tesla with almost no magnetizing current, but every reversal of the flux costs energy, and machines reverse their flux fifty to thousands of times a second. Rare-earth magnets put a strong field across an air gap with no current at all, but how strong depends on the gap they face. This lesson collects the material facts the rest of the course leans on.

  • A permanent magnet's straight demagnetization line, Bm=Br+μ0μrHm (second quadrant, H in kA/m), and the load line set by a magnet of length lm facing an air gap g of the same area: Bm=−μ0(lm/g)Hm.
  • The operating point is where they cross. A longer magnet (larger lm/g) steepens the load line and raises the flux density toward Br.
  • The magnet's energy product |BmHm| peaks when the operating point sits at Br/2; that's where a given gap field takes the least magnet.

Predict

An NdFeB magnet with Br = 1.2 T (recoil permeability 1.05) is 5 mm long and faces a 1 mm air gap of the same area. What flux density does the gap get?

Name it

Steel

Electrical steel's B–H curve rises steeply until about 1.5 T and then saturates; machines run their teeth near the knee. Every cycle around the hysteresis loop costs energy proportional to the loop's area, and changing flux induces eddy currents in the steel. Per unit mass at a fixed peak flux density,

Pcore=af+bf2

with the hysteresis term linear in frequency and the eddy term quadratic. Measuring at two frequencies separates them. Eddy loss also goes as the square of lamination thickness, so machines use stacks of 0.2 to 0.5 mm laminations insulated from each other.

Permanent magnets

A magnet's useful region is the second quadrant, where H is negative. Rare-earth and ferrite magnets are nearly straight there, Bm=Br+μ0μrHm, with recoil permeability μr near 1.05 and remanence Br of 1.1 to 1.4 T (NdFeB) or about 0.4 T (ferrite).

The load line

A magnet of length lm and area Am driving a gap g of area Ag (ideal iron) operates where its line meets Bm=−μ0lmgAgAmHm. With equal areas,

Bg=Br1+μrg/lm

The energy product

The gap's energy is supplied by the magnet: Bg2Vg/μ0=|BmHm|Vm. So the least magnet volume for a given gap field comes from operating at the maximum energy product, which for a straight-line magnet is at Bm=Br/2:

(BH)max=Br24μ0μr

NdFeB's remanence falls about 0.12% per kelvin, and too much reverse field at high temperature demagnetizes it permanently.

Worked example

A 1 mm × 10 cm² gap needs 0.6 T from an NdFeB magnet (Br = 1.2 T, μr = 1.05). What's the smallest magnet?

Show the solution
  1. Best energy product. (BH)max=Br24μ0μr=1.224μ0×1.05=273kJ/m3 about 34 MGOe.
  2. Magnet volume. Vm=Bg2Vgμ0(BH)max=0.36×10−6μ0×272800=1.05cm3
  3. Magnet shape. Operating at Bm = 0.6 T means Am=Ag, so the magnet is 10 cm² by 1.05 mm.
  4. Check. That length is μrg, as the equal-area formula requires for Bg=Br/2.

Answer the smallest magnet is 1.05 cm³, 10 cm² in area and 1.05 mm long, using NdFeB with a (BH)max of 273 kJ/m³.

Worked example

A steel loses 1.0 W/kg at 50 Hz and 1.3 W/kg at 60 Hz at the same flux density. Separate the losses and predict 400 Hz.

Show the solution
  1. Write the loss at both frequencies. With P=af+bf2: 1.0=50a+2500b1.3=60a+3600b
  2. Solve them. a=0.01167b=1.667×10−4 At 60 Hz, hysteresis is 0.70 W/kg and eddy current 0.60 W/kg.
  3. Predict 400 Hz. P=4.67+26.7=31.3W/kg dominated by eddy currents.
  4. Thinner laminations. That's why 400 Hz aircraft machines use thinner laminations: going from 0.35 mm to 0.1 mm cuts the eddy part by a factor of 12.

Answer a = 0.01167 and b = 1.667 × 10⁻⁴, so at 60 Hz the steel loses 0.70 W/kg to hysteresis and 0.60 W/kg to eddy currents. At 400 Hz it would lose 31.3 W/kg, mostly eddy current.

Worked example

A motor's NdFeB magnets (Br = 1.25 T at 20 °C, falling 0.12% per kelvin, μr = 1.05) are 4 mm long and face a 1 mm gap of the same area. How much do the gap flux and the torque per ampere fall when the magnets reach 120 °C?

Show the solution
  1. Gap field at 20 °C. Bg=Br1+μrg/lm=1.251.2625=0.990T
  2. Gap field at 120 °C. The remanence has fallen 12% to 1.10 T, so the gap field is Bg=0.871T
  3. Torque per ampere. It's proportional to the gap flux, so it falls 12% too, and the drive must supply 14% more current for the same torque, which heats the motor further.
  4. Demagnetization. Hot magnets are also easier to demagnetize, so the drive must also limit its reverse field.

Answer the gap flux falls 12%, from 0.990 T to 0.871 T, and the torque per ampere falls 12% with it, so the same torque takes 14% more current.

Check

A magnet with Br = 1.2 T and recoil permeability 1.05 is 10 mm long, facing a 2 mm gap of the same area. What's the gap flux density?

Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.

Check

What's the maximum energy product of a straight-line magnet with Br = 1.1 T and recoil permeability 1.03?

Write units the way you normally would: 1.5 kJ/m³, 1500 J/m³ and 0.0015 MJ/m³ are the same answer.

Check

A 1.5 mm × 5 cm² gap needs 0.6 T. A magnet operated at its maximum energy product of 350 kJ/m³ supplies it. How much magnet is needed?

Check

A steel loses 1.2 W/kg at 50 Hz and 1.25 times as much at 60 Hz, at the same flux density. How much of the 60 Hz loss is hysteresis?

Write units the way you normally would: 1.5 W/kg, 1500 mW/kg and 0.0015 kW/kg are the same answer.

Check

A lamination of 0.35 mm has 0.5 W/kg of eddy loss at 50 Hz. What would 0.2 mm laminations lose at 400 Hz, same flux density?

Write units the way you normally would: 1.5 W/kg, 1500 mW/kg and 0.0015 kW/kg are the same answer.

Check

An NdFeB magnet (Br = 1.2 T at 25 °C, falling 0.12% per kelvin, μr = 1.05) is 8 mm long facing a 1 mm gap of equal area. What's the gap flux density at 80 °C?

Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.

Check

A magnet (Br = 0.4 T, μr = 1.05) 6 mm long, with 1.5 times the gap's area, drives a 1 mm air gap through ideal iron.

(a)

What flux density does the magnet operate at?

Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.

(b)

What flux density does the gap get?

Check

A straight-line magnet (Br = B, recoil permeability m) l millimeters long drives a g millimeter gap of equal area.

Step 1

What is the gap flux density?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why is a machine's iron made of thin insulated laminations instead of solid steel?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.