S12 Electric machines · Practice
Magnetic materials and permanent magnets
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A magnet with = 1.2 T and recoil permeability 1.05 is 10 mm long, facing a 2 mm gap of the same area. What's the gap flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
What's the maximum energy product of a straight-line magnet with = 1.1 T and recoil permeability 1.03?
Write units the way you normally would: 1.5 kJ/m³, 1500 J/m³ and 0.0015 MJ/m³ are the same answer.
Check
A 1.5 mm × 5 cm² gap needs 0.6 T. A magnet operated at its maximum energy product of 350 kJ/m³ supplies it. How much magnet is needed?
Check
A steel loses 1.2 W/kg at 50 Hz and 1.25 times as much at 60 Hz, at the same flux density. How much of the 60 Hz loss is hysteresis?
Write units the way you normally would: 1.5 W/kg, 1500 mW/kg and 0.0015 kW/kg are the same answer.
Check
A lamination of 0.35 mm has 0.5 W/kg of eddy loss at 50 Hz. What would 0.2 mm laminations lose at 400 Hz, same flux density?
Write units the way you normally would: 1.5 W/kg, 1500 mW/kg and 0.0015 kW/kg are the same answer.
Check
An NdFeB magnet ( = 1.2 T at 25 °C, falling 0.12% per kelvin, = 1.05) is 8 mm long facing a 1 mm gap of equal area. What's the gap flux density at 80 °C?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
A magnet ( = 0.4 T, = 1.05) 6 mm long, with 1.5 times the gap's area, drives a 1 mm air gap through ideal iron.
(a)
What flux density does the magnet operate at?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
(b)
What flux density does the gap get?
Check
Gap field: = 0.38 T, = 1.05, 12 mm magnet, 1.5 mm gap?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
: = 0.35 T, = 1.02?
Write units the way you normally would: 1.5 kJ/m³, 1500 J/m³ and 0.0015 MJ/m³ are the same answer.
Check
Eddy loss: 0.3 W/kg at 50 Hz, 0.5 mm → 1000 Hz, 0.1 mm?
Write units the way you normally would: 1.5 W/kg, 1500 mW/kg and 0.0015 kW/kg are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12