S1222 of 55
0 XP
  1. Hook
  2. Problems

S12 · Midterm exam

Midterm exam: energy conversion, magnetics, transformers, rotating fields and synchronous machines

Twelve problems from lessons 1 to 20: the linear machine, magnetic materials and magnets, transformer efficiency and regulation, forces from coenergy, windings and rotating fields, generated voltage and torque, the synchronous machine in its round-rotor and salient-pole forms, its tests, operating characteristics and place in a power system, and the induction machine's slip and power flow. Give yourself two hours and work without the lessons open. "Another set" deals a different exam.

Check

A linear machine: 48 V, 0.15 Ω, a 1 m bar in 0.5 T, 5 N load.

(a)

Speed?

Write units the way you normally would: 1.5 m/s, 1500 mm/s and 0.0015 km/s are the same answer.

(b)

Efficiency?

Check

A magnet (Br = 1.1 T, μr = 1.04) of 8 mm faces a 1.2 mm gap of equal area.

(a)

Gap flux density?

Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.

(b)

Magnet length that would put it at its maximum energy product?

Check

A 50 kVA transformer: 150 W core loss, 2500 W full-load copper loss, at 0.8 load and power factor 0.8.

(a)

Efficiency?

(b)

Load of peak efficiency?

Check

An electromagnet: 200 turns, 0.5 A, two 2.5 mm gaps of 10 cm² each.

(a)

Gap flux density?

Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.

(b)

Force?

Check

A winding: q = 3, pitch 0.8.

(a)

Fundamental winding factor?

(b)

5th-harmonic winding factor?

Check

A 2-pole machine on 50 Hz.

(a)

Synchronous speed?

(b)

In rad/s?

Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.

Check

A 4-pole machine: radius 0.3 m, length 0.6 m, 0.7 T peak, 30 turns per phase, kw = 0.92, 50 Hz.

(a)

Flux per pole?

Write units the way you normally would: 1.5 Wb, 1500 mWb and 0.0015 kWb are the same answer.

(b)

Phase EMF?

Check

A rotor of 0.2 m diameter, 0.6 m long, at 12 kPa, 3000 rpm.

(a)

Torque?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

(b)

Power?

Check

A round-rotor generator with Xs = 1.2 pu delivers 0.6 pu at power factor 0.95 lagging on a 1 pu bus.

(a)

Ef?

(b)

δ?

Check

A 50 MVA, 480 V machine: rated voltage at 2 A on the OCC; SCC 45110 A per field ampere; rated current at 1.333 A.

(a)

Saturated Xs?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

(b)

SCR?

Check

A synchronous motor (Xs = 0.6 pu, Ef = 1.8 pu, 1 pu bus, 100 MVA base) carries 0.3 pu.

(a)

Load angle magnitude?

(b)

Reactive power supplied?

Write units the way you normally would: 1.5 Mvar, 1500 kvar and 0.0015 Gvar are the same answer.

Check

A salient-pole machine: Xd = 0.9, Xq = 0.5 pu, Ef = 1.8 pu, δ = 40°, 1 pu bus.

(a)

Power?

(b)

Power with the field switched off, at its best angle?

Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.

Practice

Keep practicing

16 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.