S12 Electric machines · Practice
Midterm exam
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A linear machine: 48 V, 0.15 Ω, a 1 m bar in 0.5 T, 5 N load.
(a)
Speed?
Write units the way you normally would: 1.5 m/s, 1500 mm/s and 0.0015 km/s are the same answer.
(b)
Efficiency?
Check
A magnet ( = 1.1 T, = 1.04) of 8 mm faces a 1.2 mm gap of equal area.
(a)
Gap flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
(b)
Magnet length that would put it at its maximum energy product?
Check
A 50 kVA transformer: 150 W core loss, 2500 W full-load copper loss, at 0.8 load and power factor 0.8.
(a)
Efficiency?
(b)
Load of peak efficiency?
Check
An electromagnet: 200 turns, 0.5 A, two 2.5 mm gaps of 10 cm² each.
(a)
Gap flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
(b)
Force?
Check
A winding: q = 3, pitch 0.8.
(a)
Fundamental winding factor?
(b)
5th-harmonic winding factor?
Check
A 2-pole machine on 50 Hz.
(a)
Synchronous speed?
(b)
In rad/s?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A 4-pole machine: radius 0.3 m, length 0.6 m, 0.7 T peak, 30 turns per phase, = 0.92, 50 Hz.
(a)
Flux per pole?
Write units the way you normally would: 1.5 Wb, 1500 mWb and 0.0015 kWb are the same answer.
(b)
Phase EMF?
Check
A rotor of 0.2 m diameter, 0.6 m long, at 12 kPa, 3000 rpm.
(a)
Torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Power?
Check
A round-rotor generator with = 1.2 pu delivers 0.6 pu at power factor 0.95 lagging on a 1 pu bus.
(a)
?
(b)
δ?
Check
A 50 MVA, 480 V machine: rated voltage at 2 A on the OCC; SCC 45110 A per field ampere; rated current at 1.333 A.
(a)
Saturated ?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
SCR?
Check
A synchronous motor ( = 0.6 pu, = 1.8 pu, 1 pu bus, 100 MVA base) carries 0.3 pu.
(a)
Load angle magnitude?
(b)
Reactive power supplied?
Write units the way you normally would: 1.5 Mvar, 1500 kvar and 0.0015 Gvar are the same answer.
Check
A salient-pole machine: = 0.9, = 0.5 pu, = 1.8 pu, δ = 40°, 1 pu bus.
(a)
Power?
(b)
Power with the field switched off, at its best angle?
Check
A 4-pole, 50 Hz induction motor develops 90 kW mechanical at slip 0.05.
(a)
Rotor copper loss?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
Torque?
Check
Approximate circuit: 400 V line, = 0.1, = 0.25, = 1.8 Ω, slip 0.02.
(a)
Rotor current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Air-gap power?
Check
A transformer: 0.006 + j\given0.04 pu, normally 1.7 T peak, residual flux 0.4 of peak.
(a)
Approximate regulation at pf 0.9 lagging?
(b)
Worst inrush flux (ignoring saturation)?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
A generator ( = 1.6, = 0.9 pu) feeds a 1 pu bus through 0.5 pu, delivering 0.7 of its pull-out power.
(a)
What is its pull-out power, in per unit?
(b)
At what load angle does it run?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12