Problem set 10: problems that combine magnetics, transformers, windings, synchronous and induction machines, DC and PM motors, dq models, drives and ratings

These problems draw on the whole course, and most chain several ideas: a winding's turns turned into a voltage, test data turned into an equivalent circuit and a torque, a drive's frequency turned into a speed and a slip, a duty cycle turned into a thermal rating. Work them as a review before the final.

Check

A 4-pole, 50 Hz machine: 72 series turns per phase, q = 3, pitch 0.833, gap field 0.8 T peak, rotor radius 0.1 m, length 0.2 m.

(a)

Winding factor?

(b)

Phase EMF?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

(c)

Speed?

Check

A 50 kVA transformer: core 0.2%, full-load copper 1.5%, series impedance 0.008 + j0.04 pu, at 0.9 load, pf 0.8 lagging.

(a)

Efficiency?

(b)

Approximate regulation at this load?

Check

A 100 MVA, 13.8 kV round-rotor generator with Xs = 1.6 pu delivers 1 pu at power factor 0.85 lagging.

(a)

Excitation voltage per phase?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

(b)

Pull-out power at this excitation?

Check

Motor tests: DC 10 V at 25 A; no load 460 V, 15 A, rotational loss 900 W; blocked rotor at 15 Hz: 25.88 V, 30 A, 1200 W (class A).

(a)

R2?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

(b)

X1?

(c)

Xm?

Check

Thévenin 150 V, Rth = 0.15, Xth+X2 = 1.6, R2 = 0.25 Ω; 4 poles on 60 Hz.

(a)

Slip at breakdown?

(b)

Speed at breakdown?

(c)

Breakdown torque?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

Check

A 400 V, 50 Hz, 6-pole motor rated 100 N·m on a drive at 90 Hz (constant V/f below base, constant voltage above), needing 25 rpm of slip speed.

(a)

Speed?

(b)

Drive voltage?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

(c)

Torque available at rated current?

Check

A separately excited DC motor (240 V, KaΦ = 1.5, Ra = 0.3 Ω) with field at 0.75 of rated, carrying 200 N·m.

(a)

Armature current?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

Speed?

Check

A PM DC motor: 24 V, R = 0.1 Ω, K = 0.1, no-load current 0.8 A, J = 3 × 10⁻⁵ kg·m².

(a)

Stall torque?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

(b)

Peak efficiency?

(c)

Mechanical time constant?

Check

An interior PM motor: 6 poles, λm = 0.06 Wb, Ld = 0.25 mH, Lq = 0.8 mH, 120 A; 150 V peak phase available.

(a)

MTPA id?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

Characteristic current?

(c)

Back-EMF peak at 1000 electrical rad/s, no current?

Check

A generator: Xl = 0.12, Xad = 1.4, Xfl = 0.25, Xkdl = 0.08 pu, T′′d = 0.03 s, T′d = 0.8 s, shorted from 1 pu.

(a)

Initial symmetrical current?

(b)

AC current at 0.05 s?

Check

Field-oriented control: Lm = 50 mH, Lr = 1.03 Lm, Rr = 0.35 Ω, 4 poles, 0.9 Wb, iqs = 25 A.

(a)

ids?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

Torque?

(c)

Slip?

Check

A duty cycle of 100 N·m for 3 s and 60 N·m for 40 s; a winding whose resistance has risen to 1.25 times its 25 °C value.

(a)

RMS torque?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

(b)

Winding temperature?

Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.

Practice

Keep practicing

15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.