S12 Electric machines · Practice
Problem set 10: electric machines across the course
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A 4-pole, 50 Hz machine: 72 series turns per phase, q = 3, pitch 0.833, gap field 0.8 T peak, rotor radius 0.1 m, length 0.2 m.
(a)
Winding factor?
(b)
Phase EMF?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(c)
Speed?
Check
A 50 kVA transformer: core 0.2%, full-load copper 1.5%, series impedance 0.008 + j0.04 pu, at 0.9 load, pf 0.8 lagging.
(a)
Efficiency?
(b)
Approximate regulation at this load?
Check
A 100 MVA, 13.8 kV round-rotor generator with = 1.6 pu delivers 1 pu at power factor 0.85 lagging.
(a)
Excitation voltage per phase?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Pull-out power at this excitation?
Check
Motor tests: DC 10 V at 25 A; no load 460 V, 15 A, rotational loss 900 W; blocked rotor at 15 Hz: 25.88 V, 30 A, 1200 W (class A).
(a)
?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
?
(c)
?
Check
Thévenin 150 V, = 0.15, = 1.6, = 0.25 Ω; 4 poles on 60 Hz.
(a)
Slip at breakdown?
(b)
Speed at breakdown?
(c)
Breakdown torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A 400 V, 50 Hz, 6-pole motor rated 100 N·m on a drive at 90 Hz (constant V/f below base, constant voltage above), needing 25 rpm of slip speed.
(a)
Speed?
(b)
Drive voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(c)
Torque available at rated current?
Check
A separately excited DC motor (240 V, = 1.5, = 0.3 Ω) with field at 0.75 of rated, carrying 200 N·m.
(a)
Armature current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Speed?
Check
A PM DC motor: 24 V, R = 0.1 Ω, K = 0.1, no-load current 0.8 A, J = 3 × 10⁻⁵ kg·m².
(a)
Stall torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Peak efficiency?
(c)
Mechanical time constant?
Check
An interior PM motor: 6 poles, = 0.06 Wb, = 0.25 mH, = 0.8 mH, 120 A; 150 V peak phase available.
(a)
MTPA ?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Characteristic current?
(c)
Back-EMF peak at 1000 electrical rad/s, no current?
Check
A generator: = 0.12, = 1.4, = 0.25, = 0.08 pu, = 0.03 s, = 0.8 s, shorted from 1 pu.
(a)
Initial symmetrical current?
(b)
AC current at 0.05 s?
Check
Field-oriented control: = 50 mH, = 1.03 , = 0.35 Ω, 4 poles, 0.9 Wb, = 25 A.
(a)
?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Torque?
(c)
Slip?
Check
A duty cycle of 100 N·m for 3 s and 60 N·m for 40 s; a winding whose resistance has risen to 1.25 times its 25 °C value.
(a)
RMS torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Winding temperature?
Check
A 45 kW, 1000 rpm machine is sized at 35 kPa with a length-to-diameter ratio of 1.5.
(a)
What rotor diameter does it need?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
Check
A 50 Hz generator (H = 2.5 s, = 1.3, = 1.4 pu, 0.4 pu to the bus) runs at a 25° load angle.
(a)
What is its synchronizing power coefficient (pu per radian)?
(b)
At what frequency does it swing?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A suspension magnet holds 300 kg at a 6 mm gap with 25 A.
(a)
What is its negative stiffness?
Write units the way you normally would: 1.5 MN/m, 1500 kN/m and 0.0015 GN/m are the same answer.
(b)
What proportional gain just cancels it?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12