S1221 of 55
0 XP
  1. Hook
  2. Problems

S12 · Problem set 4

Problem set 4: open- and short-circuit tests, V-curves and synchronous condensers, salient-pole machines, and the induction machine's slip, equivalent circuit and power flow

These problems cover lessons 15 to 20: reactances and short-circuit ratios from test data, excitation and reactive power at fixed load, two-reaction theory and reluctance power, and the induction machine from slip to torque. Where a problem gives no magnetizing reactance, use the approximate circuit with the magnetizing branch moved to the terminals, so that I2=V/(R1+R2/s)2+(X1+X2)2.

Check

A 2000 kVA, 480 V machine reaches rated voltage at 2.5 A of field current; its SCC rises 1347 A per field ampere, and rated short-circuit current needs 1.786 A of field current.

(a)

Saturated Xs?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

(b)

Short-circuit ratio?

(c)

Rated current?

Check

A synchronous motor (Xs = 0.7 pu) carries 0.4 pu on a 1 pu bus.

(a)

Ef for unity power factor?

(b)

Load angle at Ef = 1.7?

(c)

Reactive power supplied then (negative if absorbed)?

Check

A 25 MVA synchronous condenser with Xs = 0.8 pu on a 1 pu bus.

(a)

Reactive power supplied at Ef = 1.5 pu (negative if absorbed)?

Write units the way you normally would: 1.5 Mvar, 1500 kvar and 0.0015 Gvar are the same answer.

(b)

Its current, per unit?

Check

A salient-pole generator: Xd = 0.9, Xq = 0.55 pu, delivering 1 pu at power factor 0.9 lagging on a 1 pu bus.

(a)

Load angle?

(b)

Id?

(c)

Ef?

Check

A salient-pole machine: Ef = 1.2, Xd = 0.9, Xq = 0.75 pu on a 1 pu bus at δ = 45°.

(a)

Field term?

(b)

Reluctance term?

Check

A 4-pole, 50 Hz induction motor runs at slip 0.04 and develops 75 kW of mechanical power.

(a)

Speed?

(b)

Air-gap power?

Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.

(c)

Torque?

Check

An induction motor on 230 V (line), approximate circuit: R1 = 0.15 Ω, R2 = 0.25 Ω, X1+X2 = 1.5 Ω, at slip 0.02.

(a)

Rotor current?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

Air-gap power?

(c)

Rotor copper loss?

Check

The approximate circuit: 400 V (line), R1 = 0.1, R2 = 0.3, X1+X2 = 2 Ω, at standstill.

(a)

Starting current?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

Air-gap power at start?

Check

An induction motor: air-gap power 10 kW at slip 0.015, rotational loss 1.5 kW, stator copper and core loss 1.2 kW.

(a)

Output?

Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.

(b)

Efficiency?

Check

A slip test: phase voltage between 11 and 20 V, current between 10 and 12.5 A.

(a)

Xd?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

(b)

Xq?

Check

A 4-pole induction motor on 50 Hz at slip 0.01.

(a)

Rotor frequency?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

(b)

Speed of the rotor's field relative to the rotor?

(c)

Upper limit on rotor efficiency?

Check

A round-rotor generator (Xs = 0.7 pu, 1 pu bus) at Ef = 1.5 pu delivering 0.5 pu.

(a)

Pull-out power?

(b)

Load angle?

(c)

Reactive power delivered (negative if absorbed)?

Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.

Practice

Keep practicing

15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.