S12 Electric machines · Practice
Problem set 4: synchronous machines in operation and the induction machine
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A 2000 kVA, 480 V machine reaches rated voltage at 2.5 A of field current; its SCC rises 1347 A per field ampere, and rated short-circuit current needs 1.786 A of field current.
(a)
Saturated ?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Short-circuit ratio?
(c)
Rated current?
Check
A synchronous motor ( = 0.7 pu) carries 0.4 pu on a 1 pu bus.
(a)
for unity power factor?
(b)
Load angle at = 1.7?
(c)
Reactive power supplied then (negative if absorbed)?
Check
A 25 MVA synchronous condenser with = 0.8 pu on a 1 pu bus.
(a)
Reactive power supplied at = 1.5 pu (negative if absorbed)?
Write units the way you normally would: 1.5 Mvar, 1500 kvar and 0.0015 Gvar are the same answer.
(b)
Its current, per unit?
Check
A salient-pole generator: = 0.9, = 0.55 pu, delivering 1 pu at power factor 0.9 lagging on a 1 pu bus.
(a)
Load angle?
(b)
?
(c)
?
Check
A salient-pole machine: = 1.2, = 0.9, = 0.75 pu on a 1 pu bus at δ = 45°.
(a)
Field term?
(b)
Reluctance term?
Check
A 4-pole, 50 Hz induction motor runs at slip 0.04 and develops 75 kW of mechanical power.
(a)
Speed?
(b)
Air-gap power?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(c)
Torque?
Check
An induction motor on 230 V (line), approximate circuit: = 0.15 Ω, = 0.25 Ω, = 1.5 Ω, at slip 0.02.
(a)
Rotor current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Air-gap power?
(c)
Rotor copper loss?
Check
The approximate circuit: 400 V (line), = 0.1, = 0.3, = 2 Ω, at standstill.
(a)
Starting current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Air-gap power at start?
Check
An induction motor: air-gap power 10 kW at slip 0.015, rotational loss 1.5 kW, stator copper and core loss 1.2 kW.
(a)
Output?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
Efficiency?
Check
A slip test: phase voltage between 11 and 20 V, current between 10 and 12.5 A.
(a)
?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
?
Check
A 4-pole induction motor on 50 Hz at slip 0.01.
(a)
Rotor frequency?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
Speed of the rotor's field relative to the rotor?
(c)
Upper limit on rotor efficiency?
Check
A round-rotor generator ( = 0.7 pu, 1 pu bus) at = 1.5 pu delivering 0.5 pu.
(a)
Pull-out power?
(b)
Load angle?
(c)
Reactive power delivered (negative if absorbed)?
Check
A 1000 kVA, 4160 V machine reaches rated voltage on its OCC at 2 A of field and rated current on its SCC at 1.8 A.
(a)
What is its saturated synchronous reactance, in per unit?
(b)
And in ohms per phase?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
An 80 MVA synchronous condenser ( = 0.8 pu) runs at = 0.7 pu on a 1 pu bus.
(a)
What reactive power does it supply (negative if it absorbs)?
Write units the way you normally would: 1.5 Mvar, 1500 kvar and 0.0015 Gvar are the same answer.
Check
An induction motor runs at 0.96 of synchronous speed, delivering 15 kW of mechanical power.
(a)
What air-gap power crosses to the rotor?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
What is the rotor copper loss?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12