Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A 2-pole motor needs 60 rpm of slip speed at its load. With constant V/f at 40 Hz, how fast does it run?
Check
A 460 V, 60 Hz motor runs from a drive at 10 Hz with constant volts per hertz (no boost). What voltage does the drive apply?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A motor's breakdown torque is 400 N·m at its base frequency of 50 Hz. Above base speed the voltage is held constant. About what is its breakdown torque at 120 Hz (ignoring resistance)?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
At base speed (50 Hz) a motor is rated 200 N·m. In field weakening at 120 Hz, what torque can it carry at rated current?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A 4-pole, 50 Hz wound-rotor motor is slowed to 750 rpm with rotor resistance. What's the highest possible rotor efficiency?
Check
A 3 MW doubly fed induction generator runs over a slip range of ±0.2. About what power must its rotor converter handle?
Write units the way you normally would: 1.5 MW, 1500 kW and 0.0015 GW are the same answer.
Check
A motor rated 50 N·m at its 50 Hz base frequency, with 450 N·m of breakdown torque, is driven at 90 Hz with its voltage held at rated.
(a)
About how much torque can it carry at rated current?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
About what breakdown torque does it have, ignoring stator resistance?
Check
Speed: 4 poles, 10 Hz, 80 rpm slip?
Check
Breakdown torque at 150 Hz: 40 N·m at 50 Hz?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
DFIG converter rating: 2 MW, slip ±0.15?
Write units the way you normally would: 1.5 MW, 1500 kW and 0.0015 GW are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12