S12 Electric machines · Practice
The synchronous machine and its equivalent circuit
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A generator with = 1 pu delivers 0.5 pu current at power factor 0.95 lagging, at 1 pu terminal voltage. What's ?
Check
For the same generator ( = 1 pu, 0.5 pu current at power factor 0.95 lagging), what's the load angle?
Check
A generator's phase voltage is 2400 V and its excitation voltage 1.2 times that, with = 5 Ω, at δ = 45°. What three-phase power does it deliver?
Write units the way you normally would: 1.5 MW, 1500 kW and 0.0015 GW are the same answer.
Check
A synchronous motor on 460 V (line to line) with = 8 Ω per phase takes 10 kW at unity power factor. What's its excitation voltage per phase?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
An 800 MVA, 4.16 kV, Y-connected generator has = 1.2 pu. How many ohms per phase is that?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
What's the pull-out power of a generator with 2400 V per phase, = 1.1 times that, and = 6 Ω?
Write units the way you normally would: 1.5 MW, 1500 kW and 0.0015 GW are the same answer.
Check
A generator with a synchronous reactance of 1.2 per unit delivers rated current at rated voltage and power factor 0.8 lagging.
(a)
What is its excitation voltage, in per unit?
(b)
What is its load angle?
Check
: = 0.8 pu, 0.3 pu at pf 0.98 lagging?
Check
Power: 1000 V per phase, = 1.05 × V, 9 Ω, δ = 60°?
Write units the way you normally would: 1.5 MW, 1500 kW and 0.0015 GW are the same answer.
Check
Ohms per phase: 0.7 pu, 0.48 kV, 600 MVA?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12