How a two-energy X-ray beam hardens with depth, reconstructing a disk from its projections by filtered back-projection, echo levels from a stack of tissue layers, and the echo time that maximizes the contrast between two tissues

Lessons 37 to 41 explained how each imaging method forms its contrast. Every scanner then runs computations that turn measurements into a picture: correcting for a beam whose spectrum changes as it passes through the body, reconstructing a slice from its projections, predicting how strong each echo will be, and choosing timings that make one tissue stand out from another. In this lab you'll write a small version of each and check it against what the physics predicts.

  • Two tissues have T2 relaxation times on the sliders. The curve is the difference of their spin-echo signals, e−TE/T2a−e−TE/T2b, against echo time (equal proton density and full T1 recovery).
  • At short TE both signals are near 1 and the difference is small; at long TE both have decayed.
  • The difference peaks between the two T2 values, at TE*=ln⁡(T2a/T2b)/(1/T2b−1/T2a).

Predict

Two tissues have T2 of 100 ms and 60 ms. Which echo time gives the most contrast between them?

Name it

What the lab computes

  • Beam hardening: a beam of two equal-weight energies with attenuation coefficients μ1>μ2 transmits (e−μ1x+e−μ2x)/2 through thickness x, and its effective coefficient −ln⁡T/x falls with x as the low-energy part is filtered out. Uncorrected, this makes the center of a uniform object look less dense than its edge (cupping).
  • Filtered back-projection: for parallel projections p(s) over angles from 0 to π, convolve each with the discrete ramp filter (h0=1/4d2, hn=−1/(nπd)2 for odd n, 0 for even n), then add each filtered projection back along its lines, f(x,y)=πNθ∑θq(xcos⁡θ+ysin⁡θ), interpolating linearly between samples. A uniform disk of radius R and attenuation μ has projections 2μR2−s2.
  • Echoes: through layers of impedance Zi and thickness di, the echo from each interface has intensity RiTpath2 times the attenuation 10−αf⋅2d/10, where R is the intensity reflection coefficient ((Z2−Z1)/(Z2+Z1))2, Tpath the product of (1−R) over the interfaces passed, and α in dB/(cm·MHz).
  • MRI contrast: spin-echo signal ρ(1−e−TR/T1)e−TE/T2, and the TE that maximizes the difference between two tissues' T2 decays.

Check

Write transmit(mu1, mu2, x) returning (transmitted fraction, effective attenuation coefficient) for a two-energy beam.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Write fbp_disk(R, mu, N=32, views=60, bins=65): reconstruct an N × N image over the square from −1 to 1 from the analytic projections of a centered disk, sampled at bins points from −1 to 1.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Write echoes(layers, f, alpha=0.5): for a list of (impedance in MRayl, thickness in cm) layers, return the echo level in dB from each interface, relative to the transmitted pulse.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Write spin_echo(pd, t1, t2, tr, te) and best_te(t2a, t2b), the echo time that maximizes the difference between two tissues' T2 decays.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Explain why

Why must CT projections be filtered before they are back-projected?