Biomedical instrumentation
Specifies medical instruments by sensitivity, nonlinearity, resolution and dynamic response; designs with resistive, capacitive, piezoelectric and temperature sensors; measures with light and demodulates carriers; explains biopotentials from membrane ion gradients to the ECG's leads and axis; builds electrode and amplifier front ends that reject power-line interference with high CMRR, isolation and a driven right leg; processes ECG, EEG and EMG signals; measures blood pressure directly and with cuffs, heart sounds, valve areas, cardiac output by dilution, flow electromagnetically and by Doppler, and volumes by plethysmography; measures lung volumes and mechanics, gases, oxygen saturation and blood chemistry, and explains the clinical laboratory's analyzers; judges images by resolution, contrast and photon noise and explains X-ray, CT, ultrasound, MRI and nuclear imaging quantitatively; sizes pacemakers, defibrillators, neural stimulators, dialysis, ventilation and infusion; applies electrical safety limits; evaluates diagnostic tests and knows how devices are classified and cleared; and budgets power and links for wearable and implantable devices. Four labs compute sensor calibration and dynamics, biopotentials from membranes to leads, cardiovascular measurements from raw data, and image formation; an ECG processing lab and a pulse-oximeter project complete the set.
130 h · 56 pages · After C6, C11
Unit 1Measurement systems, sensors and optics6
Unit 2Sensors, dynamics and temperature3
Unit 3Temperature, biopotentials and the ECG4
Unit 4Electrodes, amplifiers and interference7
- Biopotential electrodes70 min
- Biopotential amplifiers70 min
- Isolation amplifiers85 min
- Interference and the driven right leg70 min
- EEG, EMG and processing biopotentials70 min
- Biopotential lab: membranes, cables, electrodes and leadsLab · 2 h
- Problem set 4: electrodes, amplifiers and interferenceProblem set · 4 h
Unit 5Biopotentials, electrodes and amplifiers1
Unit 6Pressure, flow and plethysmography7
- Direct blood-pressure measurement70 min
- Indirect blood pressure and heart sounds70 min
- Heart sounds and cardiac catheterization85 min
- Cardiac output by indicator dilution70 min
- Electromagnetic and ultrasonic flowmeters70 min
- Plethysmography and impedance measurements70 min
- Problem set 6: pressure, flow and plethysmographyProblem set · 4 h
Unit 7Catheterization, respiration, oximetry and chemistry7
- Cardiovascular lab: catheters, cuffs, dilution curves and valvesLab · 2 h
- Respiratory measurements70 min
- Respiratory mechanics and gas analysis75 min
- Pulse oximetry70 min
- Chemical biosensors70 min
- Clinical laboratory instruments75 min
- Problem set 7: catheterization, respiration, oximetry and chemistryProblem set · 4 h
Unit 8Respiration, oximetry, chemical sensors, the laboratory and X-ray imaging3
Unit 9Imaging, therapy, safety, evaluation and device design11
- Ultrasound imaging70 min
- MRI and nuclear medicine70 min
- Imaging lab: beam hardening, back-projection, echoes and MRI contrastLab · 2 h
- Pacemakers and defibrillators70 min
- Neural stimulation and recording85 min
- Therapeutic devices: electrosurgery, dialysis, ventilators and infusion pumps80 min
- Electrical safety of medical equipment70 min
- Diagnostic accuracy, device software and regulation75 min
- Designing wearable and implantable devices70 min
- Biotelemetry and implant links85 min
- Problem set 9: imaging, therapy, safety, evaluation and device designProblem set · 4 h