S15 · Lesson 3 · Resistive sensors and bridges
Potentiometric displacement sensors and their loading error, strain gauges and the gauge factor, the Wheatstone bridge with one, two and four active arms, the quarter bridge's nonlinearity, and temperature effects cancelled by bridge arrangement
Most blood-pressure transducers, load cells in hospital beds and force plates in gait labs are strain gauges: thin metal or silicon patterns whose resistance changes by a fraction of a percent when stretched. A change that small is invisible against the resistance itself, and it drifts with temperature by as much as the signal. The Wheatstone bridge, met in C1, solves both problems at once: it subtracts the unchanging part, and with the gauges arranged so that strain pushes them in opposite directions and temperature pushes them together, the drift cancels while the signal adds.
- A Wheatstone bridge excited by V with one, two or four active arms. Each active gauge changes by ±ΔR, with the signs arranged so the outputs add.
- The quarter bridge's exact output, with x = ΔR/R, bends away from the linear as x grows. The half and full bridges stay exactly linear.
- At the strains of real gauges (x of a few thousandths) the bend is a fraction of a percent, but semiconductor gauges reach x of several percent.
Predict
A 350 Ω foil gauge with gauge factor 2 is strained by 500 microstrain in a quarter bridge excited at 5 V. What's the bridge output?
ΔR/R = Gε = 2 × 500 × 10⁻⁶ = 0.001, so ΔR = 0.35 Ω. The quarter bridge gives about V(ΔR/R)/4 = 1.25 mV (exactly 1.2494 mV). Four active gauges in a full bridge would give 5 mV.
Name it
Potentiometers
A potentiometer whose wiper moves with a displacement divides its excitation in proportion, for a fraction x of travel. A load on the wiper of a pot with total resistance pulls the output down:
with the largest error near mid-travel.
Strain gauges
A conductor stretched by strain ε = ΔL/L changes resistance by . Metal foil gauges have a gauge factor G ≈ 2 (from the change in geometry plus a little piezoresistance); silicon gauges reach 100 or more, with a large temperature sensitivity.
The Wheatstone bridge
With equal arms R excited by V, one active arm R + ΔR gives exactly for x = ΔR/R. Two active arms changing in opposite senses on the same side (a half bridge) give , and four (a full bridge, two in tension and two in compression) give , both exactly linear.
Temperature
A gauge's resistance also changes with temperature, by in fractional terms, which looks like an apparent strain . Gauges in adjacent bridge arms see the same temperature, and their changes cancel in the output while opposite strains add, so half and full bridges are temperature-compensated.
Worked example
Compare the quarter-bridge output above with a full bridge of silicon gauges (G = 100) at the same strain and excitation.
Show the solution
- Foil quarter bridge. From above, it gives
- Silicon gauges' resistance change.
- Full-bridge output. two hundred times more.
- Why it matters. That's why disposable blood-pressure transducers use diffused silicon bridges.
Answer the silicon full bridge gives 250 mV, two hundred times the foil quarter bridge's 1.249 mV.
Worked example
A 10 kΩ potentiometer at mid-travel drives a 100 kΩ load. What's its error? And what apparent strain does a 1 °C change cause in a foil gauge with α = 20 ppm/°C and G = 2?
Show the solution
- Loaded potentiometer. At mid-travel:
- Its error. Against the unloaded 0.5, that's an error of 1.22% of full scale.
- Apparent strain from temperature.
- How much it matters. That's comparable to a real signal, unless a compensating gauge in an adjacent arm cancels it.
Answer the potentiometer reads 0.4878 of the supply, an error of 1.22% of full scale, and the gauge shows 10 microstrain of apparent strain per °C.
Worked example
A 120 Ω foil gauge (G = 2) sits at the end of leads with 0.5 Ω in each wire, wired as a two-wire quarter bridge. How much do the leads desensitize it, and what apparent strain appears if the copper leads warm by 10 °C (α = 0.0039/°C)?
Show the solution
- Desensitization. The 1 Ω of lead resistance in series with the gauge dilutes its change by the factor so the sensitivity falls by 0.8%.
- Lead resistance change. Warming the leads by 10 °C raises their resistance by which the bridge can't tell from strain.
- Apparent strain. a large error for a sensor that may be measuring a few hundred.
- The cure. A three-wire connection puts one lead in the gauge's arm and one in the adjacent arm, so their changes cancel.
Answer the leads cut the sensitivity by 0.8%, and warming them by 10 °C shows up as 162 microstrain of apparent strain.
Check
A 1000 Ω strain gauge with gauge factor 2.1 is strained by 200 microstrain. By how much does its resistance change?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A single active gauge (G = 2) in a bridge excited at 10 V sees 200 microstrain. About what output does the bridge give?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A quarter bridge excited at 2.5 V has its active arm changed by ΔR/R = 0.05. What's the exact output?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A bridge excited at 10 V has 4 active gauges (G = 2) at ±300 microstrain, arranged so their outputs add. What's its output?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
An uncompensated foil gauge (G = 2) has a temperature coefficient of 20 ppm/°C. What apparent strain, in microstrain, does a 10 °C change produce?
Check
A 1 kΩ potentiometer at fraction 0.5 of its travel drives a 100 kΩ load. What fraction of the excitation appears at the wiper?
Check
A 120 Ω gauge (G = 2.1) is wired as a two-wire quarter bridge through leads totaling 0.2 Ω, of copper (α = 0.0039/°C).
(a)
By what percent do the leads reduce its sensitivity?
(b)
What apparent strain does a 20 °C rise in lead temperature cause?
Check
A quarter bridge excited at V has its active arm changed by a fraction x.
Step 1
What is its exact output?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What does the linear approximation give?
Step 3
By what fraction does the approximation overstate the output?
Explain why
How do half and full bridges cancel temperature drift while keeping the strain signal?
A bridge's output depends on the difference between the fractional changes of adjacent arms. Gauges mounted so that one is stretched and its neighbor compressed change in opposite directions with strain, so their difference is twice either change and the signal adds. A temperature change, though, shifts both gauges' resistances by the same fraction in the same direction, so their difference, and the output, is unaffected. A full bridge pairs every arm this way, doubling the signal again. The same arrangement also removes the quarter bridge's nonlinearity, because the bridge's total resistance on each side stays constant as the gauges change.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.