S154 of 56
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S15 · Lesson 4 · Capacitive, inductive and piezoelectric sensors

Capacitive displacement sensors and their sensitivity, differential capacitors, inductive sensors and the LVDT with phase-sensitive detection, piezoelectric sensors as charge sources, their high-pass response, and the charge amplifier

Not every sensor is a resistor. A capacitive sensor turns a micrometer of diaphragm movement into femtofarads; an LVDT reads a position without touching it; a piezoelectric crystal produces charge when squeezed, which is how ultrasound probes, heart-sound microphones and accelerometers in wearable activity monitors work. Each has its own electrical model, and the piezoelectric one has a catch that surprises everyone the first time: it can't measure a steady force, because its charge leaks away.

  • A piezoelectric sensor squeezed by a constant force at t = 0 produces charge q = dF, giving an initial voltage q/C. The charge leaks through the amplifier's input resistance R, so the voltage decays with τ = RC.
  • The sensor is a high-pass filter with corner 1/(2πRC): fine for heart sounds and vibration, useless for a static weight.
  • A charge amplifier fixes the gain at 1/Cf regardless of cable capacitance, and a large feedback resistor sets how slowly it forgets.

Predict

A PZT disc with d = 300 pC/N and 1 nF of capacitance carries a steady 1 N load, read by an amplifier with 1 GΩ input resistance. What does the voltage do?

Name it

Capacitive sensors

A parallel-plate capacitor, C=ε0εrA/d, changes when the gap d moves. For a small change Δd, ΔC≈−CΔd/d: sensitivity rises as the gap shrinks. A differential capacitor, a center plate between two fixed ones, makes one capacitance rise as the other falls, which doubles the sensitivity and cancels the leading nonlinearity. Capacitive pressure sensors and MEMS accelerometers work this way, read with AC excitation.

Inductive sensors and the LVDT

A coil's inductance depends on its magnetic path, L=N2/ℛ, so moving a core changes it. The linear variable differential transformer has one primary and two series-opposed secondaries; a centered core gives zero output, and the output amplitude grows linearly with displacement with a phase of 0° or 180° for the two directions. Phase-sensitive demodulation (multiplying by the excitation and low-pass filtering, as in C11's lock-in) recovers a signed DC output.

Piezoelectric sensors

Quartz, PZT ceramic and PVDF film produce charge in proportion to force: q=dF, with d about 2.3 pC/N for quartz and several hundred pC/N for PZT. Electrically the sensor is a charge source in parallel with its capacitance C. Across a resistance R the voltage is a high-pass response,

VF(jω)=dCjωτ1+jωτ,τ=RC

A charge amplifier, an op amp with feedback capacitor Cf (and a large resistor across it), holds the sensor at virtual ground and outputs −q/Cf, independent of the sensor's and cable's capacitance.

Worked example

A capacitive sensor has 1 cm² plates 0.1 mm apart in air. What's its capacitance, and how much does it change for a 1 µm displacement?

Show the solution
  1. Capacitance. C=8.854×10−12×10−410−4F=8.85pF
  2. Change for 1 µm. ΔC=C×1μm100μm=88.5fF
  3. Can it be read? A 1% change is one an AC bridge or capacitance-to-digital converter can resolve easily.

Answer the sensor has 8.85 pF, which changes by 88.5 fF (1%) for a 1 µm displacement.

Worked example

The predict question's disc feeds a charge amplifier with Cf = 100 pF instead. What's the output for a 1 N force step?

Show the solution
  1. Charge amplifier output. Vo=−qCf=−300pC100pF=−3V whatever the cable's capacitance.
  2. Static loads. With a 10 GΩ resistor across Cf, the time constant is 1 s again, so it still can't hold a static load.
  3. What the charge amplifier gains. The gain no longer depends on the cable.

Answer the output is −3 V for the 1 N step, whatever the cable's capacitance.

Worked example

A differential capacitive sensor has a center plate between two 1 cm² plates, each 0.1 mm away in air. Find both capacitances when the center plate moves 1 µm, and the ratio (C1−C2)/(C1+C2) a bridge would report.

Show the solution
  1. At rest. Each capacitance is C0=8.854pF
  2. After a 1 µm move. C1=ϵ0Ad−x=8.943pFC2=ϵ0Ad+x=8.766pF a difference of 0.177 pF.
  3. Bridge ratio. It works out exactly to C1−C2C1+C2=xd=0.01 The two hyperbolic curves combine into a perfectly linear output.
  4. What it doesn't depend on. The ratio doesn't depend on the permittivity or the area, which is why precision displacement and pressure sensors use the differential form.

Answer C1 = 8.943 pF and C2 = 8.766 pF, and the bridge reports exactly x/d = 0.01, a perfectly linear output.

Check

A capacitive sensor has 1 cm² plates 0.05 mm apart with relative permittivity 4. What's its capacitance?

Write units the way you normally would: 1.5 pF and 0.0015 nF are the same answer.

Check

A 20 pF parallel-plate sensor has a 50 µm gap. How much does its capacitance change when the gap shrinks by 2 µm?

Write units the way you normally would: 1.5 fF and 0.0015 pF are the same answer.

Check

A piezoelectric sensor with d = 150 pC/N and 10 nF of capacitance is suddenly loaded with 0.5 N. What voltage appears at first?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A piezoelectric sensor of 0.5 nF is read across 1 GΩ. What's its low-frequency corner?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

Check

A piezoelectric sensor with d = 100 pC/N drives a charge amplifier with Cf = 1000 pF. What's the size of the output for a 0.2 N force step?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A piezoelectric sensor jumps to 1 V under a steady load and is read across 2 GΩ with 2 nF of capacitance. What's left after 0.2 s?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A differential capacitor has 1 cm² plates, each 50 µm from a center plate in air, which moves 5 µm.

(a)

What is C1−C2?

Write units the way you normally would: 1.5 pF and 0.0015 nF are the same answer.

(b)

What is (C1−C2)/(C1+C2)?

Check

A piezoelectric sensor with charge sensitivity k pC/N is loaded with F newtons.

Step 1

How much charge does it produce, in pC?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why can't a piezoelectric sensor measure a constant force, and why does a charge amplifier help even though it doesn't fix that?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.