S15 · Problem set 1
Problem set 1: sensitivity, nonlinearity and resolution, first- and second-order sensor dynamics, strain gauges and bridges, capacitive and piezoelectric sensors, and phase-sensitive and optical detection
These problems cover lessons 1 to 5: transducer outputs and nonlinearity, input-referred resolution and combined errors, step, ramp and sinusoid responses of first-order probes, catheter amplitude ratios and overshoot, gauge resistance changes and bridge outputs, loaded potentiometers, capacitive and piezoelectric sensor signals, phase-sensitive demodulation, fibers and photodiodes.
Check
A transducer of 5 µV/V/mmHg at 3 V excitation; separately, an output with a = 0.004 µV/mmHg² over 0 to 200 mmHg at the same s.
(a)
Output at 250 mmHg?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(b)
Nonlinearity against the endpoint line, in percent?
Check
A gain of 2000 into a 12-bit converter spanning 3 V; independent errors 1.5, 0.4 and 1 mmHg.
(a)
Input-referred step?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
(b)
Combined error in mmHg?
Check
A probe with τ = 8 s meets a 1.5 °C step.
(a)
Remaining error after 40 s?
(b)
Time to come within 0.2 °C?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A first-order probe with τ = 10 s.
(a)
Lag behind a ramp of 0.5 °C/min?
(b)
Amplitude ratio at 0.5 Hz?
Check
A catheter system with = 20 Hz and ζ = 0.15.
(a)
Amplitude ratio at 15 Hz?
(b)
Step overshoot in percent?
Check
A 350 Ω gauge with G = 2 at 300 microstrain, in a bridge excited at 10 V.
(a)
Resistance change?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Approximate quarter-bridge output?
(c)
Output if four such gauges form a full bridge?
Check
A quarter bridge at 3 V with ΔR/R = 0.03 in its active arm.
(a)
Exact output?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(b)
Percent error of the linear approximation?
Check
A foil gauge (G = 2) with a 15 ppm/°C temperature coefficient; a 2 kΩ pot at 0.5 of its travel with a 20 kΩ load.
(a)
Apparent strain for an 8 °C change, in microstrain?
(b)
Wiper output as a fraction of the excitation?
Check
A capacitive sensor: 0.5 cm² plates 0.1 mm apart, relative permittivity 5.
(a)
Capacitance?
Write units the way you normally would: 1.5 pF and 0.0015 nF are the same answer.
(b)
Change for a 4 µm gap reduction?
Check
A piezoelectric sensor with d = 150 pC/N and 4 nF, read across 5 GΩ, under a 0.5 N step.
(a)
Initial voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Low-frequency corner?
(c)
Voltage after 1 s?
Check
A charge amplifier with = 500 pF reads a sensor with d = 100 pC/N; a transducer whose sensitivity falls by a fraction 0.006 per °C.
(a)
Output size for 0.3 N?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Percent gain error after 4 °C?
Check
A heart rate of 60 per minute whose first 8 harmonics must be reproduced by a catheter with = 80 Hz and ζ = 0.6.
(a)
Highest harmonic needed?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
Percent error in that harmonic's amplitude?
Check
An LVDT's 4 kHz carrier reaches a phase-sensitive demodulator with an in-phase amplitude of 60 mV at 15° to the reference, plus 40 mV of quadrature pickup from cable capacitance.
(a)
Average output from the in-phase signal?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(b)
Average output with the quadrature pickup added?
(c)
Resistor for a 10 Hz RC output filter with 220 nF?
Check
A fiber with core index 1.49 and cladding 1.4 carries 5 µW at 880 nm to a photodiode with quantum efficiency 0.85.
(a)
The fiber's numerical aperture?
(b)
Acceptance half-angle in air?
(c)
Photocurrent?
Write units the way you normally would: 1.5 µA, 1500 nA and 0.0015 mA are the same answer.
Check
A 120 Ω gauge (G = 2.1) measures 200 microstrain through two-wire leads totaling 0.5 Ω of copper (0.0039/°C), which warm by 25 °C during the test.
(a)
What strain does the bridge indicate, before the leads warm?
(b)
How much apparent strain does the warming add?
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.