S1611 of 56
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S16 · Lesson 11 · Noise-control enclosures

Boxing in a noisy machine, why an enclosure's insertion loss falls short of its walls' transmission loss unless it's lined, how small leaks cap the result, the stiffness-controlled low-frequency region of close-fitting enclosures, and lagging pipes and ducts

The most direct way to quiet a machine is to put it in a box. Lesson 10 showed how much a wall blocks; an enclosure of the same panels usually blocks much less, for two reasons that catch out first designs. Sound trapped inside builds up until it pushes through the walls nearly as hard as the bare machine radiated, and a gap of one percent of the surface undoes most of a good wall. Fixing both is cheap once they're understood: line the inside, seal the edges.

  • The curve is an enclosure's insertion loss, how much quieter the machine becomes once boxed, against the average absorption coefficient of its inside surface, for wall transmission loss and open-area fraction on the sliders.
  • An unlined steel box (α ≈ 0.02) loses 17 dB of its walls' transmission loss; lining it to α = 0.5 recovers most of it.
  • A leak caps the curve: with 1% of the surface open, no wall does better than about 20 dB.

Predict

A steel enclosure's walls have 30 dB of transmission loss, but its inside is bare (average absorption 0.05). How much quieter does it make the machine?

Name it

Insertion loss of an enclosure

A machine radiating power W into an enclosure builds a diffuse field whose intensity on the walls is about W/Ai, with Ai=α¯S the inside absorption. The walls pass a fraction τ of the intensity striking them, so the power escaping is WτS/Ai, and the insertion loss is

IL=10log⁡AiτS=TL+10log⁡α¯

valid for ᾱ small compared with 1 and τ small compared with ᾱ. A bare enclosure, ᾱ = 0.02 to 0.05, gives up 13 to 17 dB of its walls' rating; a lined one with ᾱ of 0.5 or more comes within a few decibels.

Leaks

Openings add transmission at τ = 1, so the walls' composite transmission coefficient is (1−s)τ+s for an open fraction s, and the composite loss can't exceed −10log⁡s: 20 dB for 1% open, 30 dB for 0.1%. Cable penetrations, door seals and ventilation openings must be sealed or fitted with lined, bent ducts (silencers) that pass air but not sound.

Low frequencies and close-fitting enclosures

When the enclosure fits close around the machine, the air gap acts as a spring between the vibrating surface and the panel, resonating at f=12πρc2/md for panel surface density m and gap d. Below and near that frequency the enclosure can amplify rather than reduce noise; it must be either loose-fitting or tuned so the resonance falls below the noise's spectrum.

Lagging

Wrapping a noisy pipe or duct with a porous layer and an impervious outer skin (lagging) works the same way: the porous layer decouples the skin from the vibrating wall and absorbs, and the skin's mass blocks. The same mass–air–mass resonance limits it at low frequency.

Worked example

A machine needs 25 dB of insertion loss. The walls can be 1 mm steel (TL ≈ 30 dB at the frequencies that matter) or 2 mm steel (TL ≈ 36 dB). What inside absorption does each need?

Show the solution
  1. 30 dB walls. From IL = TL + 10 log ᾱ: α¯≥10−5/10=0.32
  2. 36 dB walls. α¯≥10−11/10=0.079
  3. Choosing. A modest lining in the thicker box, or a thick absorbent lining in the thinner one, both work. Doubling the steel changes how much lining is needed, but the box still needs one.

Answer the 1 mm walls need an average absorption coefficient of at least 0.32 inside, and the 2 mm walls at least 0.079.

Worked example

A well-lined enclosure with 40 dB walls has 0.1% of its surface open around cables. What composite transmission loss do its walls have now, and with 1% open?

Show the solution
  1. With 0.1% open. The composite transmission coefficient is τ¯=0.999×10−4+0.001=0.0011 or 29.6 dB, down by 10 dB from a gap a thousandth of the area.
  2. With 1% open. τ¯=0.99×10−4+0.01=0.0101 or 20.0 dB.
  3. What matters now. The 40 dB walls no longer matter, and sealing is what helps.

Answer 29.6 dB with 0.1% open and 20.0 dB with 1% open.

Worked example

A close-fitting cover of 5 kg/m² sheet sits 50 mm from a gearbox. Where is its mass–air resonance, and what does that mean for a 100 Hz gear-mesh tone?

Show the solution
  1. Mass–air resonance. f=12πρc2md=12π1.2×34325×0.05=120Hz
  2. The 100 Hz tone. It sits just below the resonance, where the trapped air couples the cover strongly to the gearbox and the cover may radiate more than the bare gearbox did.
  3. Move the cover out. At 200 mm the resonance drops to f=12π1.2×34325×0.2=60Hz putting the tone above it, where the cover isolates.

Answer the resonance is at 120 Hz, just above the 100 Hz tone, so the cover may radiate more than the bare gearbox; moved out to 200 mm, its resonance drops to 60 Hz and it isolates the tone.

Check

An enclosure's walls have 30 dB of transmission loss and an average inside absorption of 0.02.

(a)

What insertion loss does it give?

(b)

How much of the walls' rating does the buildup cost?

Check

A wall of 35 dB transmission loss has a fraction 0.0001 of its area open.

(a)

What composite transmission loss does it have?

(b)

What is the most any wall could give with that opening?

Check

An enclosure must give 15 dB of insertion loss with walls of 30 dB transmission loss.

(a)

What average inside absorption coefficient does it need?

Check

A close-fitting cover of 5 kg/m² sits 25 mm from a vibrating machine surface (air: ρ = 1.2 kg/m³, c = 343 m/s).

(a)

Where is its mass–air resonance?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

(b)

What gap would put the resonance at 50 Hz?

Check

A machine of 85 dB sound power level sits in an enclosure of 6 m² inside surface with average absorption 0.5.

(a)

What reverberant sound pressure level builds up inside?

Check

Why does lining an enclosure's inside with absorbent raise its insertion loss even though the lining blocks almost no sound itself?

Check

An enclosure has walls of transmission loss T dB, an open fraction s and average inside absorption ᾱ.

Step 1

What composite transmission loss do its walls have?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does an unlined enclosure fall so far short of its walls' transmission loss?

Practice

Keep practicing

8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.