S16 Acoustics · Practice
Noise-control enclosures
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
0 solved
0 in a row
0 of 8 kinds solid
Check
An enclosure's walls have 30 dB of transmission loss and an average inside absorption of 0.02.
(a)
What insertion loss does it give?
(b)
How much of the walls' rating does the buildup cost?
Check
A wall of 35 dB transmission loss has a fraction 0.0001 of its area open.
(a)
What composite transmission loss does it have?
(b)
What is the most any wall could give with that opening?
Check
An enclosure must give 15 dB of insertion loss with walls of 30 dB transmission loss.
(a)
What average inside absorption coefficient does it need?
Check
A close-fitting cover of 5 kg/m² sits 25 mm from a vibrating machine surface (air: ρ = 1.2 kg/m³, c = 343 m/s).
(a)
Where is its mass–air resonance?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What gap would put the resonance at 50 Hz?
Check
A machine of 85 dB sound power level sits in an enclosure of 6 m² inside surface with average absorption 0.5.
(a)
What reverberant sound pressure level builds up inside?
Check
Insertion loss: TL 25 dB, ᾱ = 0.03?
Check
Composite TL: 30 dB with 0.0005 open?
Check
Mass–air resonance: 3 kg/m², 40 mm?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S16