S162 of 56
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S16 · Lesson 2 · Vibration isolation

Keeping vibration out of a structure or a sensitive instrument, transmissibility and why isolation only starts above √2 times the natural frequency, mounts chosen by their static deflection, the damping trade-off, two-stage mounts, and tuned vibration absorbers

A pump bolted to a floor shakes the building; the same pump on springs barely disturbs it. An electron microscope on a bare floor blurs with the footsteps next door; on a soft mount it doesn't. Both are the oscillator of lesson 1, used backward: instead of making something ring, the goal is to make a resonance sit so far below the disturbing frequency that hardly any force gets through. The physics fits on one curve, and the design comes down to choosing a spring.

  • The curve is the transmissibility of a spring-mounted mass, the fraction of a vibrating force (or base motion) that gets through the mount, against the ratio r of the disturbing frequency to the mount's natural frequency, for the damping ratio on the slider.
  • Below r = √2 the mount makes things worse, with a peak at resonance limited only by damping. Above √2 it isolates, increasingly with frequency.
  • More damping tames the resonance but lets more through at high frequency: the price of a quieter start-up is poorer isolation in running.

Predict

A 50 Hz motor sits on springs that compress 5 mm under its weight. With 5% damping, what fraction of its vibrating force reaches the floor?

Name it

Transmissibility

A mass m on a mount of stiffness k and damping c has natural frequency f0=12πk/m. The ratio of force transmitted to the foundation to force applied, or equally of the mass's motion to a vibrating base's, is

T=1+(2ζr)2(1−r2)2+(2ζr)2,r=ff0

At r = √2, T = 1 whatever the damping; above it T falls, at high frequency as 2ζ/r with damping and as 1/r2, 40 dB per decade, without.

Choosing a mount

Since k=mg/δ, the natural frequency depends only on the static deflection: f0=12πg/δ≈15.8/δmm Hz. Good isolation needs r of 3 or more, so a machine running at 25 Hz needs a mount deflecting at least about 3.5 mm, and floor-borne disturbances at a few hertz need soft air springs. Damping is a compromise: it limits the peak a machine passes through while starting, but spoils isolation above resonance; elastomer mounts with ζ of 0.05 to 0.1 are a common balance.

Two stages

Putting an intermediate mass between two sets of springs makes a two-stage mount whose transmissibility falls as 1/r4, 80 dB per decade, above its second resonance: the approach used for sensitive instruments and for the suspensions of gravitational-wave detectors.

Tuned absorbers

When a structure resonates near a forcing frequency, a small mass on a spring tuned to that frequency can cancel its motion. With mass ratio μ (absorber to structure), Den Hartog's optimum tunes the absorber to fa=f0/(1+μ) with damping ζopt=3μ/[8(1+μ)3], which flattens the response over a band rather than leaving two sharp peaks. Tall buildings and long footbridges carry such dampers.

Worked example

Repeat the predict question with 30% damping. What has the extra damping bought and cost?

Show the solution
  1. Isolation at 30% damping. At r = 7.09 and ζ = 0.3, 2ζr = 4.26, so T=1+4.262(1−50.3)2+4.262=0.088 a 21 dB reduction instead of 32.
  2. Peak at start-up. A starting motor passes through the resonance at 7 Hz, which now peaks at T=1+0.360.6≈1.9 instead of about 10.
  3. The usual compromise. Many installations keep light damping and add snubbers or briefly lock the mount during start-up instead.

Answer the extra damping lowers the start-up resonance peak from about 10 to 1.9, and it costs isolation at 50 Hz: a 21 dB reduction instead of 32.

Worked example

An optical table must reduce 10 Hz floor vibration. What does a mount with a 2 Hz natural frequency and 5% damping achieve, and what static deflection would steel springs need for that?

Show the solution
  1. Frequency ratio. r=10/2=5
  2. Transmissibility. With ζ = 0.05, 2ζr = 0.5, so T=1+0.25242+0.25=0.047 a 27 dB reduction.
  3. Static deflection. A 2 Hz spring mount would sag under the table's weight by δ=g(2πf0)2=62mm
  4. Why air springs. That's impractical for steel springs, which is why such tables float on pneumatic legs whose stiffness comes from compressed air.

Answer the mount passes 0.047 of the vibration, a 27 dB reduction, but steel springs would need 62 mm of static deflection, so such tables use pneumatic legs.

Worked example

A floor slab resonates near the 2 Hz pace of walking. A tuned mass damper of 5% of the slab's modal mass is added. How should it be tuned and damped?

Show the solution
  1. Tuning. Den Hartog's rule, with μ = 0.05: fa=f01+μ=21.05=1.90Hz
  2. Damping. ζ=3×0.058×1.053=0.127
  3. What it does. Tuned slightly below the structure and fairly heavily damped, the absorber spreads the single resonant peak into two low, broad ones, so footfalls near 2 Hz no longer build up large motions.

Answer tune the damper to 1.90 Hz and give it a damping ratio of 0.127.

Check

A machine running at 15 Hz sits on mounts that deflect 5 mm under its weight, with damping ratio 0.1.

(a)

What is the mount's natural frequency?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

(b)

What is its transmissibility in decibels (negative means isolation)?

Check

A machine runs at 30 Hz, and its mount should place the disturbance at 3 times the natural frequency.

(a)

What natural frequency should the mount have?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

(b)

What static deflection does that require?

Check

A mount with damping ratio 0.2 is driven at 1 times its natural frequency.

(a)

What is its transmissibility?

Check

A structure with a resonance at 1.5 Hz gets a tuned mass damper of mass ratio 0.05.

(a)

To what frequency should it be tuned?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

(b)

What damping ratio should it have?

Check

Well above resonance with negligible damping, compare a single-stage mount with a two-stage mount whose two resonances both sit near the same frequency, at 10 times it.

(a)

What transmissibility does the single stage give, in decibels?

(b)

Roughly what does the two-stage mount give (falling as 1/r4)?

Check

Why does adding damping to a mount make its isolation worse well above resonance?

Check

A machine running at f Hz sits on a mount that deflects δ meters under its weight, with damping ratio ζ.

Step 1

What is the mount's natural frequency?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does a vibration mount only isolate above √2 times its natural frequency, and amplify below it?

Practice

Keep practicing

8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.