S16 Acoustics · Practice
Vibration isolation
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
0 solved
0 in a row
0 of 8 kinds solid
Check
A machine running at 15 Hz sits on mounts that deflect 5 mm under its weight, with damping ratio 0.1.
(a)
What is the mount's natural frequency?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What is its transmissibility in decibels (negative means isolation)?
Check
A machine runs at 30 Hz, and its mount should place the disturbance at 3 times the natural frequency.
(a)
What natural frequency should the mount have?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What static deflection does that require?
Check
A mount with damping ratio 0.2 is driven at 1 times its natural frequency.
(a)
What is its transmissibility?
Check
A structure with a resonance at 1.5 Hz gets a tuned mass damper of mass ratio 0.05.
(a)
To what frequency should it be tuned?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What damping ratio should it have?
Check
Well above resonance with negligible damping, compare a single-stage mount with a two-stage mount whose two resonances both sit near the same frequency, at 10 times it.
(a)
What transmissibility does the single stage give, in decibels?
(b)
Roughly what does the two-stage mount give (falling as )?
Check
Frequency ratio: 25 Hz on a mount deflecting 2 mm?
Check
Transmissibility: r = 3, ζ = 0.05?
Check
Den Hartog damping for μ = 0.03?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S16