S629 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S6 · Lesson 29 · Noise in microwave systems

Noise temperature and noise figure, cascades and the Friis formula, lossy lines, Y-factor measurement and receiver sensitivity

A receiver's job is to pull a weak signal out of noise, and every component it contains adds a little more. Physics II and the thermal-physics course introduced Johnson noise and the noise temperature; here they become the working tools of receiver design. The key result is Friis's formula for a cascade: the first stage's noise counts in full, but each later stage's noise is divided by the gain in front of it. That's why a satellite dish puts a low-noise amplifier right at the feed, why a meter of lossy cable before that amplifier costs as much as its own noise figure, and why the order of the blocks in a receiver matters so much.

  • The noise figure of a three-stage receiver, an LNA, a passive mixer (7 dB loss, 7 dB noise figure) and an IF amplifier (NF 3 dB), against the LNA's gain, with an optional lossy cable in front.
  • With enough LNA gain the total approaches the LNA's own noise figure plus the cable loss; with too little, the mixer's noise shows through.
  • Every decibel of cable loss before the LNA adds a full decibel to the system noise figure, whatever the LNA's gain.

Predict

A receiver has an LNA (NF 1 dB, gain 20 dB) followed by a mixer (NF 7 dB, loss 7 dB). What happens to the system noise figure if the two are swapped, mixer first?

Name it

Noise temperature and noise figure

  • A resistor at temperature T delivers available noise power kTB to a matched load: −174 dBm in 1 Hz at T0 = 290 K.
  • A noisy two-port's equivalent noise temperature Te is the extra input temperature that would account for its output noise.
  • Noise figure F=(S/N)in(S/N)out with a 290 K source, so F=1+Te/T0, and NF = 10 log F.

Cascades (Friis)

Te=Te1+Te2G1+Te3G1G2+⋯,F=F1+F2−1G1+F3−1G1G2+⋯

(gains as power ratios, available gains strictly).

Lossy components

A matched attenuator of loss L (as a power ratio) at physical temperature T has G=1/L and Te=(L−1)T. At T = 290 K its noise figure equals its loss: a 2 dB cable has NF 2 dB. Cooling it lowers its noise; that's why radio telescopes cool their feeds.

Measuring noise: the Y-factor method

A calibrated noise source switches between a hot temperature Th and a cold one Tc (often 290 K). The ratio of the output noise powers, Y=Nh/Nc, gives

Te=Th−YTcY−1

With Tc=T0 and the source's excess noise ratio ENR = 10log⁡Th−T0T0: NF = ENR − 10 log(Y − 1) in dB.

Sensitivity

The weakest signal a receiver can detect with a required SNR:

Smin (dBm)=−174+10log⁡B+NF+SNRmin

(B in Hz). With an antenna of noise temperature TA, the system temperature is Tsys=TA+Te and the noise power is kTsysB.

Worked example

Find the noise figure of an LNA (NF 1 dB, gain 20 dB), a mixer (NF 7 dB, conversion loss 7 dB) and an IF amplifier (NF 3 dB) in cascade. What does a 1 dB cable before the LNA do?

Show the solution
  1. Cascade noise factor. F=1.259+5.012−1100+1.995−1100×0.1995=1.259+0.040+0.050=1.349
  2. Noise figure and temperature. That's NF = 1.30 dB and Te = 101 K.
  3. Add the cable. A 1 dB cable at 290 K multiplies F by 1.259: NF = 2.30 dB and Te = 202 K, twice the noise temperature.

Answer the cascade's noise figure is 1.30 dB (Te = 101 K); the 1 dB cable raises it to 2.30 dB and doubles Te to 202 K.

Worked example

A noise source with ENR 15 dB gives a Y-factor of 12 dB on an amplifier. What's the amplifier's noise figure?

Show the solution
  1. Hot temperature. Th=290(1+101.5)=9461K
  2. Y-factor. 12 dB is Y = 15.85.
  3. Noise temperature. Te=9461−15.85×29014.85=328K
  4. Noise figure. NF=10log⁡(1+328/290)=3.28dB
  5. Check with the shortcut. It gives the same: 15−10log⁡(14.85)=3.28dB

Answer 3.28 dB.

Worked example

A radio telescope's LNA has Te = 20 K and sits behind a feed with 0.2 dB of loss. What does the feed add at room temperature, and if it is cooled to 20 K? The sky contributes 10 K.

Show the solution
  1. Feed loss. L=100.02=1.047
  2. Feed at 290 K. It adds its own noise and scales the LNA's: (L−1)T=13.7K1.047×20=20.9K 34.6 K in all, and a system temperature of 44.6 K with the sky.
  3. Feed cooled to 20 K. The feed adds only 0.9 K: 21.9 K, and 31.9 K with the sky.
  4. Integration time. Cooling a fifth of a decibel of loss cuts the integration time for a given sensitivity by (44.6/31.9)2=2.0 which is why observatories cool everything in front of the first amplifier.

Answer at room temperature the feed adds 13.7 K and raises the LNA's share to 20.9 K, for a 44.6 K system; cooled to 20 K it adds only 0.9 K, for a 31.9 K system and half the integration time.

Check

What's the equivalent noise temperature of an amplifier with a 1.2 dB noise figure?

Write units the way you normally would: 1.5 K and 1500 mK are the same answer.

Check

An amplifier with NF 1.5 dB and gain 10 dB feeds a stage with NF 12 dB. What's the cascade's noise figure?

Check

A matched 2 dB attenuator sits at a physical temperature of 20 K. What's its equivalent noise temperature?

Write units the way you normally would: 1.5 K and 1500 mK are the same answer.

Check

A noise source of ENR 15 dB produces a Y-factor of 3 dB. What's the noise figure?

Check

A receiver has 200 kHz bandwidth, 2 dB noise figure and needs 15 dB SNR. What's its sensitivity?

Check

An antenna with noise temperature 50 K feeds a receiver with 0.4 dB noise figure. What's the system noise temperature?

Write units the way you normally would: 1.5 K and 1500 mK are the same answer.

Check

A line with 1 dB of loss at 77 K feeds an amplifier with a 3 dB noise figure.

(a)

What is the pair's equivalent noise temperature?

Write units the way you normally would: 1.5 K and 1500 mK are the same answer.

(b)

What is its noise figure?

Check

A matched attenuator of loss ratio L at temperature T precedes an amplifier with noise temperature t.

Step 1

What is the attenuator's noise temperature?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does loss in front of a receiver's first amplifier hurt so much more than loss after it?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.