S6 RF and microwave engineering · Practice
Noise in microwave systems
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
What's the equivalent noise temperature of an amplifier with a 1.2 dB noise figure?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
Check
An amplifier with NF 1.5 dB and gain 10 dB feeds a stage with NF 12 dB. What's the cascade's noise figure?
Check
A matched 2 dB attenuator sits at a physical temperature of 20 K. What's its equivalent noise temperature?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
Check
A noise source of ENR 15 dB produces a Y-factor of 3 dB. What's the noise figure?
Check
A receiver has 200 kHz bandwidth, 2 dB noise figure and needs 15 dB SNR. What's its sensitivity?
Check
An antenna with noise temperature 50 K feeds a receiver with 0.4 dB noise figure. What's the system noise temperature?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
Check
A line with 1 dB of loss at 77 K feeds an amplifier with a 3 dB noise figure.
(a)
What is the pair's equivalent noise temperature?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
(b)
What is its noise figure?
Check
for NF 1.5 dB?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
Check
Cascade NF: 1 dB, 12 dB gain, then 12 dB?
Check
Sensitivity: 30 kHz, NF 3 dB, SNR 12 dB?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S6