S9 Feedback control · Practice
Problem set 11: controller design problems
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
Design a lead for whose zero cancels the pole at −2, placing the closed-loop poles at .
(a)
Where does the lead's pole go?
(b)
What is ?
(c)
What overshoot should the step response show?
Check
A PI controller with = τ cancels the pole of to give a closed-loop time constant of 0.5 × τ.
(a)
What ?
(b)
How long does a setpoint step take to settle within 2%?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A PID cancels both poles of for a closed-loop time constant of 1 s.
(a)
What ?
(b)
What ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(c)
What ?
Check
A process gets a SIMC PI with = θ.
(a)
What ?
(b)
What , the smaller of τ and ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A relay of ±0.5 drives a loop into a 10 s limit cycle of amplitude 0.1. Tune a Ziegler–Nichols PID.
(a)
What ?
(b)
What ?
Check
A lead must add 45° at the new crossover of 10 rad/s.
(a)
What pole-to-zero ratio α does it need?
(b)
Where does its zero go?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A lag raises by 5 with its zero a decade below the 5 rad/s crossover.
(a)
Where does its pole go?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
How much phase does it cost at crossover?
Check
A plant gets state feedback for = 50 rad/s, ζ = 0.7, and an observer three times faster with the same damping, measuring y.
(a)
What is ?
(b)
What is the observer gain ?
Check
A plant gets an LQR with Bryson's weights: x should stay within 0.1 and u within 12.
(a)
What is q/r?
(b)
Where is the closed-loop pole?
Check
A random walk with step variance 0.01 is measured with noise variance 0.1.
(a)
What is the steady-state Kalman gain?
Check
A plant (τ in ms) is sampled every 10 ms. Design a deadbeat proportional gain.
(a)
What puts the pole at z = 0?
(b)
What fraction of the setpoint does the output reach?
Check
A plant gets proportional control for a 45° phase margin.
(a)
What gain?
(b)
What gain margin does that leave, as a factor?
Check
A Smith predictor controls with a PI ( = τ) designed for = 3 s on the delay-free model.
(a)
What ?
(b)
With a perfect model, when does a setpoint step settle within 2%?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S9