S9 Feedback control · Practice
Problem set 4: identification, feedforward and cascade control
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A step of 4 changes a process output by 10 in the end. The output reaches 28.3% of its change 6 s after the step, and 63.2% another 1.5 s later. Fit an FOPDT model and tune a SIMC PI with = θ.
(a)
What is τ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
What is θ?
(c)
What is ?
Check
A plant is reduced by the half rule and given a SIMC PI with = θ.
(a)
What dead time does the reduced model have?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
What results?
(c)
What , the smaller of τ and 8θ?
Check
Sampled every 50 ms, a plant's data fit . A PI controller with = τ is to give a closed-loop time constant of 2 × τ.
(a)
What is τ?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(b)
What gives that closed loop?
Check
A sine test at 2 Hz on a first-order plant reads a gain of 3 and a phase of −30°. A proportional gain = 10 then closes the loop.
(a)
What is the plant's DC gain?
(b)
Where is the closed-loop pole (as a positive rate)?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A loop's step response overshoots 15% and rings with a period of 0.2 s.
(a)
What damping ratio does a second-order fit give?
(b)
What 2% settling time does the fit predict?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A plant gain near 2 is estimated by least squares from 500 samples of an input with mean square 4, with output noise σ = 0.02.
(a)
What relative standard deviation does the estimate have?
Check
A motor (J = 0.0001 kg·m², viscous friction b = 0.0002 N·m·s, = 0.08 N·m/A) follows a trapezoidal profile: acceleration 2000 rad/s² up to a cruise speed of 100 rad/s.
(a)
What feedforward current is needed just before cruise begins?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
And during the cruise?
Check
A static feedforward cancels a measured disturbance (gain 0.5) using a model of the input gain 1 that is 30% off; the feedback loop's low-frequency gain is 20.
(a)
How much of a unit disturbance reaches the output without feedback?
(b)
And with the feedback loop as well, at low frequency?
Check
A PI controller ( = 3, = 8) drives .
(a)
Where is the closed-loop zero?
(b)
What is the closed-loop ?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(c)
And ζ?
Check
A PI controller with = 1, = 3 and setpoint weight b = 0.2 sees a setpoint step of 10 with the output at rest.
(a)
How big is its output's initial jump?
(b)
At what rate does its integral term then begin to rise?
Check
A servo motor ( = 0.03 N·m/A, J = 5 × 10⁻⁵ kg·m²) gets a proportional speed loop crossing over at 150 Hz, around a current loop 10 times faster.
(a)
What speed gain, in amperes per rad/s?
Write units the way you normally would: 1.5 A/(rad/s), 1500 mA/(rad/s) and 0.0015 kA/(rad/s) are the same answer.
(b)
What phase margin does the speed loop keep?
Check
A drive's current loop has a 1 kHz bandwidth; its speed loop is 5 times slower and its position loop 10 times slower than that.
(a)
What bandwidth does the position loop have?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What following error does it leave at 300 rad/s, without feedforward?
Check
A temperature loop crosses over at 0.02 rad/s; the steam valve under it has a flow loop crossing at 0.5 rad/s.
(a)
How much extra does the flow loop attenuate a supply-pressure upset at the temperature loop's crossover?
(b)
What phase margin would the temperature loop keep if its own plant were an integrator?
Check
A speed loop clamps its current command at 10 A. The motor has = 0.05 N·m/A and J = 0.0001 kg·m².
(a)
What's the least time to reach 1000 rad/s from rest?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A grid inverter's current loop has gain 20 at −100° at the line frequency 60 Hz; it's sampled at 20 kHz.
(a)
What percentage tracking error does a PI controller leave at the line frequency?
(b)
How many samples of memory would a repetitive controller need?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S9