S9 Feedback control · Practice
Resonant and repetitive control
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
0 solved
0 in a row
0 of 7 kinds solid
Check
At the reference frequency, a loop has gain 10 and phase −90°. What percentage of the reference appears as tracking error?
Check
A repetitive controller sampled at 10 kHz rejects a disturbance with a 50 Hz period. How many samples of memory does its delay line need?
Check
A repetitive controller's delay line holds N = 200 samples. Up to how many harmonics of the fundamental do its poles cover, to the Nyquist frequency?
Check
A damped PR controller with = 100 and = 2 rad/s is tuned to 50 Hz. What is its resonant term's gain at 1 Hz above 50 Hz?
Check
Simulate repetitive control. A plant (a direct feedthrough for simplicity) suffers a periodic disturbance with period N = 20. The controller learns with , where (the reference is zero) and g = 0.9, starting from for the first samples. Run 40 periods and set rms_first and rms_last, the RMS error over the first and last periods.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
What percentage tracking error results from a loop gain of 3 at −100°?
Check
How many delay-line samples does repetitive control need for a 60 Hz period at 8 kHz?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S9