S9 Feedback control · Practice
Sensitivity and fundamental limitations
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
0 solved
0 in a row
0 of 10 kinds solid
Check
At some frequency a loop gain has magnitude 1 and phase −100°. How much are disturbances at that frequency amplified (|S|)?
Check
A loop of relative degree two has right-half-plane poles at +2 and, if not zero, +0 rad/s. What's ?
Check
A plant has an RHP zero at +10 and an RHP pole at +1 rad/s. What's the smallest peak sensitivity achievable?
Check
A boost converter has L = 47 µH, a 5 Ω load and duty cycle 0.3. Where's its right-half-plane zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A stable loop holds |S| at 1/2 for all ω below 1 rad/s. If the compensating rise is spread evenly from 1 to 20 rad/s (and |S| = 1 above), what |S| does that band have?
Check
By the rule , how fast must the loop balancing a 0.5 m inverted pendulum cross over?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
At some frequency a loop gain has magnitude 1 and phase −120°.
(a)
What is |S| there?
(b)
And |T|?
Check
|S| for |L| = 0.3 at −120°?
Check
Lowest with an RHP zero at 6 and pole at 0.5?
Check
Boost RHP zero: L = 100 µH, R = 2 Ω, D = 0.2?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S9