Meter A (σ = 0.015 pu) reads 0.8 and meter B (σ = 0.05 pu) reads 0.84 for the same flow. What's the weighted least-squares estimate, in per unit?
Check
For those two meters (σ = 0.01 and 0.02 pu), what's the standard deviation of the estimate, in per unit?
Check
An estimator has 30 measurements and 5 state variables. How many degrees of freedom does its chi-square test have?
Check
A residual is 0.03 pu and the residual's standard deviation is 0.006 pu. What's its normalized residual?
Check
A meter has σ = 0.01 pu, and its row of has diagonal entry 0.005² pu². What's the standard deviation of its residual, in per unit?
Check
A reading is off from its estimate by 0.3 pu with σ = 0.01 pu. How much does that one residual add to J?
Check
Two meters read the same flow: 0.98 pu (σ = 0.01) and 1.1 pu (σ = 0.05).
(a)
What is the WLS estimate?
(b)
What is J?
Check
WLS estimate from 0.86 (σ = 0.022) and 0.61 (σ = 0.041)?
Check
Normalized residual: r = 0.014, = 0.0048?
Check
Degrees of freedom for 78 measurements and 3 states?