Ohmwork
0 XP
S10Senior depth

Power system analysis

Works in three-phase complex power and the per-unit system; models transformers and overhead lines from their geometry, including bundling, charging and long-line effects; rates lines thermally and predicts their sag; predicts real and reactive power flow, voltage drop and voltage collapse with loadability and reactive margins, and sizes series and shunt compensation; builds, reduces and modifies the bus admittance and impedance matrices; follows surges along lines and cables and sizes line-commutated HVDC converters; solves power flow by Gauss–Seidel, Newton–Raphson and the DC approximation, models tap changers and phase shifters; predicts flows after outages with distribution factors; models synchronous generators, their capability limits and their excitation control; dispatches generation economically with penalty factors, commits units against start-up costs, and explains congestion and locational prices; estimates the system state from redundant measurements and finds bad data; judges generation adequacy by loss-of-load expectation; analyzes frequency control from inertia to AGC; computes symmetrical, unsymmetrical and open-conductor faults with sequence networks; sets overcurrent, distance and differential relays; judges transient stability with the swing equation and the equal-area criterion and small-signal stability from mode damping; and accounts for inverter-based resources, distribution feeders and power quality. Four labs compute line parameters, long-line constants and traveling waves, economic dispatch with losses and prices, fault currents from Z-bus, and swing curves with critical clearing; a power-flow lab writes a Y-bus builder, power injections and Gauss–Seidel in Python; the project completes a Newton–Raphson power-flow program with PV buses, branch flows and fault calculations.

0%0 of 56 pages

Test out of S10Already know this? Answer a few questions from its final exam, pass, and the whole course counts as finished.

130 h · 56 pages · After C3, A13, with D1 as the on-ramp

Unit 1Power, per unit, transformers and line parameters5
  1. The power system and complex power70 min
  2. The per-unit system70 min
  3. Transformers in power systems70 min
  4. Transmission line parameters70 min
  5. Problem set 1: power, per unit, transformers and line parametersProblem set · 4 h
Unit 2Line models, power transfer, compensation and network matrices7
  1. Transmission line models70 min
  2. Power transfer and voltage70 min
  3. Reactive power compensation70 min
  4. Surges, traveling waves and HVDC transmission85 min
  5. The bus admittance and impedance matrices70 min
  6. Kron reduction, sparsity and building the impedance matrix75 min
  7. Problem set 2: line models, power transfer, compensation and network matricesProblem set · 4 h
Unit 3Ampacity, voltage stability and line computations4
  1. Line ampacity and sag2 h
  2. Voltage stability2 h
  3. Line lab: parameters, long lines and traveling wavesLab · 2 h
  4. Problem set 3: ampacity, voltage stability and line computationsProblem set · 4 h
Unit 4Power flow7
  1. The power-flow problem70 min
  2. Gauss–Seidel power flow70 min
  3. Newton–Raphson power flow70 min
  4. Fast decoupled and DC power flow70 min
  5. Regulating transformers in the power flow70 min
  6. Contingency analysis70 min
  7. Problem set 4: power flowProblem set · 4 h
  1. Midterm examMidterm · 4 h
Unit 5Generators, dispatch, markets, frequency and estimation8
  1. Synchronous generators in the power system70 min
  2. Generator capability and excitation2 h
  3. Economic dispatch70 min
  4. Transmission losses and unit commitment70 min
  5. Optimal power flow and locational prices70 min
  6. Frequency control70 min
  7. State estimation1.5 h
  8. Problem set 5: generators, dispatch, markets, frequency and estimationProblem set · 4 h
Unit 6Capability, adequacy and dispatch3
  1. Generation adequacy and reliability2 h
  2. Dispatch lab: economic dispatch, losses and pricesLab · 2 h
  3. Problem set 6: capability, adequacy and dispatchProblem set · 4 h
Unit 7Faults and protection6
  1. Symmetrical faults70 min
  2. Symmetrical components70 min
  3. Unsymmetrical faults70 min
  4. Sequence networks of a system and open-conductor faults70 min
  5. Power system protection70 min
  6. Problem set 7: faults and protectionProblem set · 4 h
Unit 8Stability, inverter-based resources and distribution7
  1. Fault lab: Z-bus and fault currents in codeLab · 2 h
  2. The swing equation65 min
  3. The equal-area criterion70 min
  4. Multimachine and small-signal stability70 min
  5. Inverter-based resources and the changing grid70 min
  6. Distribution systems and power quality70 min
  7. Problem set 8: stability, inverter-based resources and distributionProblem set · 4 h
Unit 9Faults, protection and stability by computation2
  1. Stability lab: swing curves and critical clearingLab · 2 h
  2. Problem set 9: faults, protection and stability by computationProblem set · 4 h
Unit 10Power systems across the course3
  1. Power-flow lab: Y-bus, injections and Gauss–SeidelLab · 2 h
  2. Project: a Newton–Raphson power-flow programProject · 2 h
  3. Problem set 10: power systems across the courseProblem set · 4 h
Unit 11Power system design problems1
  1. Problem set 11: power system design problemsProblem set · 4 h
Unit 12Operating the grid1
  1. Problem set 12: operating the gridProblem set · 4 h
  1. Final examFinal exam · 4 h