S15 Biomedical instrumentation · Practice
Problem set 4: electrodes, amplifiers and interference
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
An electrode with = 0.5 kΩ, = 80 kΩ and = 0.2 µF.
(a)
Corner frequency?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
Impedance magnitude at 50 Hz?
(c)
Impedance at DC?
Check
Electrode offsets of 150 mV into a stage that swings ±3 V; half-cell potentials 0.8 and 0.34 V; a 5 MΩ microelectrode with 5 pF.
(a)
Largest DC-coupled gain?
(b)
Voltage between the two half-cells?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(c)
Microelectrode bandwidth?
Check
An instrumentation amplifier with = 2 kΩ, = 20 kΩ and a second stage of 5.
(a)
Gain?
(b)
Further gain needed for a total of 2000?
Check
An amplifier with differential gain 500 and common-mode gain 0.005, facing 40 mV of common-mode voltage.
(a)
CMRR?
(b)
Input-referred common-mode error?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
Check
5 mV of common-mode voltage, electrodes differing by 10 kΩ, a common-mode input impedance of 500 MΩ; a difference stage of gain 10 with resistors of tolerance 0.0005.
(a)
Mismatch-induced differential voltage?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
(b)
Worst-case CMRR of the difference stage?
Check
A 120 V, 50 Hz line couples to a patient through 5 pF; the patient is grounded through 80 kΩ.
(a)
Displacement current?
Write units the way you normally would: 1.5 µA, 1500 nA and 0.0015 mA are the same answer.
(b)
Common-mode voltage?
Check
3 nA coupled into one lead with 10 kΩ of electrode mismatch; a 3 µT, 50 Hz field through a 0.1 m² loop.
(a)
Differential pickup from the lead current?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
(b)
Magnetically induced voltage?
Check
A driven-right-leg circuit with = 2 MΩ, = 10 MΩ, = 50 kΩ and 0.1 µA of displacement current.
(a)
Common-mode voltage?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(b)
Effective ground impedance?
Check
A common-mode voltage of 5 mV must leave less than 0.5 µV of error.
(a)
Required CMRR?
(b)
As a plain ratio?
Check
A 128-channel recorder sampling at 2000 per second with 18-bit converters spanning 2.5 V.
(a)
Step size?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
(b)
Data rate?
Check
A first-order high-pass at 0.05 Hz; a 60 Hz notch with Q = 50.
(a)
Time constant?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
Phase lead at 1 Hz?
(c)
Notch width?
Check
An evoked response of 0.5 µV in 15 µV of background, with stimuli delivered 5 times per second.
(a)
Sweeps for an SNR of 6?
(b)
Recording time?
Check
An electrode pair presents 50 kΩ at 37 °C, recording a 1000 µV signal over 100 Hz.
(a)
How much thermal noise does it add?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
(b)
What signal-to-noise ratio does that alone allow?
Check
Two electrodes present 20 and 10 kΩ at 60 Hz (treat them as resistive) to an amplifier with 100 MΩ common-mode input impedance; 20 mV of common mode is present.
(a)
What differential error does the mismatch create?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
Check
A notch filter at 50 Hz has Q = 10.
(a)
How wide a band does it remove?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What is the time constant of its ringing after a step?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S15